FMA4X, FMA4P: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

6

A150158

Fig. 6 – Wiring Layout Air Conditioning Unit

(Cooling and 1-Stage Heat)

A150159

Fig. 7 – Wiring Layout Heat Pump Unit

 (Cooling and 2-Stage Heat)

A11048

Fig. 8 – FMA4X ECM Motor Speed Taps

R

G

W

Y

THERMOSTAT

R

G

W

1

C

FAN COIL

(CONTROL)

C

Y

AIR COND.

RED

RED

GRN

WHT

B

YELLOW

C

R

G

C

E

L

O

Y

THERMOSTAT

R

R

C

O

Y

G

C

W

1

W

2

W

2

FAN COIL

(CONTROL)

HEAT PUMP

(CONTROL)

RED

GRN

B

WHT

WHT

ORANGE

YELLOW

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury. 
Sheet metal parts may have sharp edges or burrs. Use care and wear

appropriate  protective  clothing,  safety  glasses  and  gloves  when

handling parts. 

WARNING

!

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury or death.

Disconnect all power to unit before servicing field wires or removing

control package. The disconnect (when used) on access panel does not

allow safe service to all other parts of unit. 

If  unit  does  not  have  a  disconnect,  disregard  the  foregoing.  Instead,

make  sure  that  a  disconnecting  means  is  within  sight  from,  and  is

readily accessible from, the unit.

Disconnect  all  electrical  power  to  unit  before  performing  any

maintenance or service on it. Lock out and tag switch with a suitable

warning label. 

1   2   3   4   5

Speed Taps may be located on motor,
or on plug close to motor.

CL

G

N

1   2   3   4   5

Summary of Contents for FMA4X

Page 1: ...installed in unconditioned space NOTE Nuisance sweating may occur if the unit is installed in a humid location with low airflow Units are designed for upflow applications only Local codes may limit this free air return type unit to installation in single level applications INSTALLATION Check Equipment Unpack unit and move to final location Remove carton taking care not to damage unit Remove protec...

Page 2: ...into place install refrigerant tubing as follows 1 Route tubing to connection points taking care not to block service access 2 Remove plugs from liquid and vapor lines 3 Braze connections using either silver bearing or non silver bearing brazing material Do not use soft solder materials which melt below 800 F 427 C Consult local code requirements Always flow nitrogen through the system refrigerant...

Page 3: ...r NOTE Unit is intended for non ducted return air applications Product Data sheet includes a list of accessories including louvered wall panels and return air opening grills If ducted return is used airflow must meet criteria established in the Product Data Local codes may limit this unit to single level applications Design the duct system in accordance with ACCA Manual 0 Design for Residential Wi...

Page 4: ...sured along low voltage wire use No 16 AWG color coded insulated 35 C minimum wire A13092 Fig 5 Transformer Connections NOTE Before proceeding with electrical connections make certain that voltage frequency and phase correspond to that specified on rating plate Also check to be sure that the service provided by utility is sufficient to handle additional load imposed by this equipment Refer to unit...

Page 5: ...motor and Time Delay Board TDB For units with ECM motor the off delay is programmed into the motor Follow Table 2 ECM Motor Speed Taps the corresponding blower off delays for each speed tap CONTINUOUS FAN Thermostat closes R to G G energizes and completes circuit to indoor blower motor When G is de energized there is a 90 s blower off delay COOLING MODE Thermostat energizes R to G R to Y and R to ...

Page 6: ...t metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing safety glasses and gloves when handling parts WARNING ELECTRICAL OPERATION HAZARD Failure to follow this warning could result in personal injury or death Disconnect all power to unit before servicing field wires or removing control package The disconnect when used on access panel does not allow safe servi...

Page 7: ...92 530 Med 845 801 759 716 675 626 573 510 Low 676 640 602 563 523 499 FMA4P3000AL High 1367 1312 1252 1192 1131 1063 990 908 821 Med 1211 1165 1114 1065 1016 960 899 833 748 Low 992 952 912 873 828 782 728 656 627 FMA4P3600AL High 1397 1345 1290 1263 1196 1116 1051 980 907 Med 1298 1252 1198 1147 1094 1037 976 910 842 Low 1149 1105 1056 1008 960 909 856 791 726 Table 5 ECM Airflow Performance Sta...

Reviews: