Table 54: 25 ton to 50 ton supply and return air duct configurations
Supply air
Return air
Outside air
Exhaust air
Unit configuration
Bottom
Left
Right
Top
Bottom
Left
Right
Top
Front
Left
Right Side* Front
Yes
Yes
Yes
Yes
-
Yes
-
-
-
-
Yes
-
Yes
Yes
Yes
Yes
Yes
-
-
Yes
-
-
Yes
-
-
Yes
Yes
Yes
Yes
Yes
Yes
-
-
Yes
-
Yes
Yes
Yes
Yes
Cooling only
Yes
Yes
Yes
Yes
-
-
-
-
Yes
Yes
Yes
Yes
-
Yes
Yes
-
-
-
Yes
-
-
-
-
Yes
-
Yes
Yes
Yes
-
-
-
-
Yes
-
-
Yes
-
-
Yes
Yes
Yes
-
-
Yes
-
-
Yes
-
Yes
Yes
Yes
Yes
Cooling with discharge
through heat section
Yes
Yes
-
-
-
-
-
-
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
-
Yes
-
-
-
-
Yes
-
Yes
Yes
Yes
Yes
Yes
-
-
Yes
-
-
Yes
-
-
Yes
Yes
Yes
Yes
Yes
Yes
-
-
Yes
-
Yes
Yes
Yes
Yes
Cooling with heat and
discharge plenum
or cooling with
downstream section
and discharge plenum
Yes
Yes
Yes
Yes
-
-
-
-
Yes
Yes
Yes
Yes
-
Cooling with ERW and
discharge through heat
section
Yes
Yes
-
-
Yes
-
-
-
-
-
Yes
Yes
Yes
Cooling with heat with
ERW with downstream
section and discharge
plenum
Yes
Yes
Yes
Yes
Yes
-
-
-
-
-
Yes
Yes
Yes
Table 55: 60 ton to 80 ton supply and return air duct configurations
Supply air
Return air
Outside Air
Exhaust air
Unit configuration
Bottom
Left
Right
Bottom
Left
Left
Right
Side*
Front
Yes
Yes
Yes
-
Yes
-
Yes
-
Yes
Yes
Yes
Yes
-
-
-
-
-
-
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Cooling only
Yes
Yes
Yes
-
-
-
-
-
-
Yes
Yes
-
-
Yes
-
Yes
-
Yes
Yes
Yes
-
-
-
-
-
-
-
Yes
Yes
-
Yes
-
Yes
Yes
Yes
Yes
Cooling with discharge
through heat section
Yes
Yes
-
-
-
-
-
-
-
Yes
Yes
Yes
-
Yes
-
Yes
-
Yes
Yes
Yes
Yes
-
-
-
-
-
-
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Cooling with heat and
discharge plenum
or cooling with
downstream section
and discharge plenum
Yes
Yes
Yes
-
-
-
-
-
-
Note:
*Exhaust air side is opposite of outside air side.
Top return with return fan or ERW is not available.
Discharge panel
For horizontal discharge units with a blank section,
the discharge panel can be field adjusted from one
side of the unit to the other.
1. Remove six screws (25 ton to 50 ton) or eight
screws (60 ton to 80 ton) (Figure 44) and panel
cleats that hold the discharge panel in place
2. Remove the panel and relocate to the
opposite side of the unit.
3. At the new location for the discharge panel,
install a gasket on the flanges identified by
arrows in Figure 44.
4. Install the panel in the opening, and secure
using the six or eight panel cleats and screws
removed in step 1.
Tempmaster
®
Omni™ Premier 25 Ton to 80 Ton Rooftop Units Installation and Maintenance Guide
82
Tempmaster