GENERAL

The GME Underceiling Indoor Unit are
designed to be coupled with the OSA
outdoor units and controlled by the HAN-L6
room temperature controller. Units must be
installed in accordance with all national and
local safety codes.

Combinations

One GME 152 with one OSA 45
One GME 222 with one OSA 73
One GME 302 with one OSA 100/101
One GME 402 with one OSA 126/127
One GME 502 with one OSA 147/148/150
One GME 702 with one OSA 180/181

One GME unit c/w HAN-L6 Controller and
one GME unit without controller (slave) can
be connected in tandem to one single
circuit Outdoor Unit. Tandem combinations
available are:

Two GME 152 with one OSA 73
Two GME 152 with one OSA 85
Two GME 222 with one OSA 126/127
Two GME 302 with one OSA 180/181
Two GME 402 with one OSA 220/221

One GME 222 and GME 152 (slave) with
one OSA100/101

UNPACKING UNITS

The OSA outdoor unit and GME indoor unit
are cartoned separately.  Unpack each
item carefully.  Examine for transit damage.

INSTALLATION

Positioning & Mounting

The GME is designed to be installed :
a. suspended horizontally beneath a level

or sloping ceiling, or

b.  floor or wall mounted (i.e. vertically).

Note

:  For an extra low profile the unit can

be recessed into the ceiling (or wall).

Preparation

Prior to mounting the GME the mounting
brackets must be detached from each end
of the unit.
1. Open the end filter panel and locate the

screw securing the unit endcaps (refer
figure 2).

2. Remove the endcap securing screw and

retain.

3. Remove the endcap by first sliding it

forward approx. 20 mm, then pull
outwards away from end of the unit.

4. Release each mounting bracket from

behind the two bolts securing them to
the unit.

5. Remove the floor mounting base from

the back of the GME if when ceiling
mounted it is required to fit flush to the
wall.

Underceiling Mounting

Locate the GME near a wall to take full
advantage of the long supply air throw and
to hide the condensate drain pipe (and
other connections) exiting at the rear of the
unit.

Refrigeration and wiring connections  are
via the top or the rear access holes. A right-
angled suction pipe extension is supplied to
facilitate top exit.

Fig. 3   Mounting Detail

30 mm
MAXIMUM

MOUNTING ROD

MOUNTING
BRACKET

GME 152:  942 mm
GME 222, 302: 1203 mm
GME 402 – 702: 1803 mm

Underceiling Installation

1. If an extra low profile installation is

preferred, first cut the required ceiling
aperture.

Fig. 1   Mounting Options

OPTIONAL

WALL

MOUNTING

(RECESSED)

UNDERCEILING

MOUNTING

Fig. 2

Mounting Bracket Detachment

ENDCAP

MOUNTING
BRACKET

HINGED DOWN
FILTER PANEL

SCREW SECURING

ENDCAP

MOUNTING ROD CENTRES

VIEWED FROM BELOW

GME UNIT

Components

The GME carton includes:
1.  GME indoor unit.
2.  HAN-L6 Wall Control (shipped inside

unit behind filter panel)

3.  Insulated condensate drain extension kit.
4. Right-angled suction pipe extension

c/w lock nut and teflon seal.