background image

Installation Instructions and 

Homeowner’s Manual

20007890  5/08   Rev. 8

DO NOT STORE OR USE 
GASOLINE OR OTHER 
FLAMMABLE VAPORS AND 
LIQUIDS IN THE VICINITY OF 
THIS OR ANY OTHER 
APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

• 

Do not try to light any appliance. 

• 

Do not touch any electric switch; 

do not use any phone in your 

building. 

• 

Immediately call your gas 

supplier from your neighbor’s 

phone. Follow the gas suppliers 

instructions. 

• 

If you cannot reach your gas 

supplier call the fire department.

WARNING! 

IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE OR 
EXPLOSION MAY RESULT 
CAUSING PROPERTY DAMAGE, 
PERSONAL INJURY OR LOSS 
OF LIFE.

PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND 
USING APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

FOR YOUR SAFETY
Installation and service must 
be performed by a qualified 
installer, service agency or the 
gas supplier.

Builder Top Vent Direct 
Vent Zero Clearance Gas 
Fireplace Heater 
Models:  33TDVDSN,    

 

 

36TDVDSN,    

 

 

39TDVDSN

7636 

TDVN cover

5/04

WARNING:  Improper installation, 
adjustment, alteration, service or 
maintenance can cause injury or 
property damage. Refer to this 
manual. For assistance or additional 
information, consult a qualified 
installer, service agency or the gas 
supplier.

CERTIFIED

DESIGN

CERTIFIED

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Summary of Contents for 33 TDVDSN

Page 1: ... MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE INSTALLER CONSUMER SAFETY INFORMATION FOR YOUR SAFETY Installation and service must be performed by a qualified installer service agency or the gas supplier Builder Top Vent Direct Vent Zero Clearance Gas Fireplace Heater Models 33TDVDSN 36TDVDSN 39TDVDSN 7636 TDVN cover...

Page 2: ...Restrictor Plate 33TDVDSN only 18 Venting Components 20 Operating Instructions Glass Information 21 Louvre Removal 21 Window Frame Assembly Removal 21 Glass Cleaning 21 Installation of Logs Lava Rock Ember Material 22 Lighting Operating Instructions 24 Troubleshooting 25 Fuel Conversion Instructions 26 Maintenance Unit Adjustment 28 Maintenance 29 Replacement Parts 31 Optional Accessories Fan Kits...

Page 3: ... fireplace for at least ten four 4 hours the first time you use it If the optional fan kit has been installed place the fan switch in the OFF position during this time For high altitude installations refer to Unit Adjustment on Page 28 WARNING Check with your electronics manufacturer before installing a television or other electronic de vice above this fireplace 4 Under no circumstances should this fi...

Page 4: ...t vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes car...

Page 5: ...mm H 6 152 mm 7 181 mm 7 190 mm I 5 149 mm 6 171 mm 6 159 mm J 7 200 mm 10 254 mm 8 213 mm K 11 297 mm 13 343 mm 12 318 mm L 1 18 mm 1 18 mm 1 18 mm Framing Dimensions M 29 737 mm 35 889 mm 35 889 mm N 33 851 mm 36 927 mm 39 1003 mm O 14 368 mm 16 419 mm 16 419 mm P 49 1264 mm 55 1403 mm 56 1422 mm Q 24 632 mm 28 714 mm 28 718 mm R 35 894 mm 39 1010 mm 40 1016 mm 7636 TDVN specs 5 04 F N Rough Ope...

Page 6: ...a bay window trim kit does not effect the distances and reference points referred to in the diagram and chart Noncombustible mantels and legs may be installed at any height and width around the appliance When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant to prevent discoloration Clearance to Combustibles A B C D E V W X Y Z Fireplace CFM146 DV Mantel Chart...

Page 7: ...the facing material of the wall The strips are adjustable to 1 2 13 mm 5 8 16 mm or 3 4 19 mm Fig 4 5 Screw through the slotted holes in the drywall strip and into the pre drilled holes in the fireplace side Measure from the face of the fireplace to the face of the drywall strip to confirm the final depth High Elevations Input ratings are shown in BTU per hour and are certified without deration for ele...

Page 8: ... off is shipped in the control valve compartment Using two wrenches tighten the flexible tube at the shut off valve and at the gas control 3 When using a flex connector use only approved fittings When a union is installed provide easy access in its placement for servicing Refer to gas specification for pressure details and ratings 4 When a vertical section of gas pipe is required for the installation ...

Page 9: ...nt termination be located observ ing the minimum clearances as shown on the following page The EB 1 Electrical junction box has been fitted stand ard on this model to allow for the easy connection of an optional fan kit To connect the EB 1 box to the house electrical supply follow the steps below 1 Unscrew retaining screw from EB 1 base plate Fig 8 and remove the EB 1 assembly from the appli ance 2...

Page 10: ...outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other appliances appliances 10 000 Btuh 3kW and 23cm for appliances 10 000 100 000 Btuh 30kW 36 91 cm Btuh 3kW and 50 000 Btuh for appliances 100 000 Btuh 30kW 15kW 12 30 cm for appliances 50 ...

Page 11: ...ply High Tem perature Sealant Hose Clamp FP1471a Fig 8 Apply high temperature sealant to 4 and 7 pipes Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors G Combustible 6 152 mm Noncombustible 2 51 mm F Combustible 6 152 mm Noncombustible 2 51 mm G Balcony with no side wall M Combustible Noncombustible 12 305 mm M B...

Page 12: ...n from the floor of the fireplace is 11 3 4 m the horizontal run to the face of the outer wall must not exceed 14 4 3 m Example B If the vertical dimension from the floor of the unit is 7 2 14 m the horizontal run to the face of the outer wall must not exceed 8 2 6 m Horizontal dimension from the outside face of the wall to the center of the fireplace vent flange Sidewall vent graph showing the relatio...

Page 13: ...237 Fig 12 Maximum horizontal vent run 7 5 2 3m A B A B 17 5 2m Max 1 x 90 elbow in horizontal plane 3 914mm FP1238 Fig 13 Maximum vent run with elbows The maximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of the horizontal run MUST be reduced ...

Page 14: ...rews 2 8 Screws 2 Adjustable Zero Clearance Sleeve 8 Screws 2 Adjustable Zero Clearance Sleeve ZCS101 Fig 16 Adjustable zero clearance sleeve Firestop VO584 100 Vent Opening 2 99 djt Vent Opening for Combustible Wall 9 240mm 9 240mm Fireplace Hearth Framing Detail Opening for Noncombustible Wall 7 190mm VO584 100 Fig 15 Locate vent opening on wall STEP 3 Place fireplace into position Fig 17 Measure...

Page 15: ...3 914 mm with metal pipe straps Make sure the horizontal vent pipe is in stalled on a level horizontal plane Vertical Sidewall Installation Flex Vent Pipe NOTE The 40 1016 mm flex vent is used for 90 off the top of the unit then out the back wall Follow Step 1 and 2 on Page 13 Step 3 Install the four 4 spacer springs on the 4 flex vent pipe When installing the spacer springs around the 4 pipe stretc...

Page 16: ... Min Window Well Gravel Drain BG402 Fig 24 Below grade installation Zero Clearance Sleeve if required A minimum of 24 610mm ver tical pipe must be installed when using the 7TDVSNORK Kit The 22 559 mm vertical rise center to center of the snorkel may be included for calculationof max horizontal run 24 610 mm Minimum Screws Foundation Wall 6 165mm FP1475 flex 90 bend 4 04 djt FP1475 Fig 23 Bend flex ...

Page 17: ...xample Maximum horizontal length 0 x 45 elbows 10 3 m 1 x 45 elbows 8 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 2 4 m vertical rise Two sets of 45 elbows offsets within these vertical installations From 0 to a maximum of 8 2 4 m of vent pipe can be used between elbows Fig 27 7DVCS must be used to support offsets Fig 33 This application will require that you first determine the roof pitch and us...

Page 18: ...m 5 Place fireplace into position 6 Place firestop s 7DVFS or Attic Insulation Shield 7DVAIS into position and secure Fig 32 7 Install roof support Fig 33 and roof flashing making sure upper flange of flashing is below the shingles Fig 34 8 Install appropriate pipe sections until the venting is above the flashing Fig 34 9 Install storm collar and seal around the pipe 10 Add additional vent lengths for p...

Page 19: ...installed on both the bottom and the top side of the ceiling joists If an attic is above ceiling level a 7DVAIS Attic Insulation Shield must be installed The enlarged ends of the vent section always face downward Fig 34 CFM190 TTR Ternim 2 1 25 02 sta CFM190 Fig 35 Minimum termination to roof clearance Min 2 610 mm ...

Page 20: ...g Twist Lock Pipe Model 7FDVSK Sidewall Venting Flex Vent Pipe Starter Kit Model 7TDVSKV Vertical Venting for 7TDVSKV A order 1 12 to 6 12 roof pitch for 7TDVSKV B order 7 12 to 12 12 roof pitch for 7TDVSKV F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS Snorkel Kit Twist Lock Pipe Model 7FDVSKS Snorkel Kit Flex Vent Pipe 45o Elbow 7TDV45 for Rear Vent to Vertical Vent or V...

Page 21: ...on the glass It is therefore recommended that the glass be cleaned two or three times with a non ammonia based household cleaner and warm water We recommend gas fireplace glass cleaner within the first few weeks of operation After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house The use of any non appro...

Page 22: ...ns provided with pins on back logs and grooves on the center log 6 Place platinum embers loosely along top surface of burner along entire length of ported area of front burner DO NOT place embers on back portion of burner Use individual pieces of embers no larger than dime size about 1 16 thick fluffed up thick ness Use a single layer of embers and DO NOT overlap pieces Ember material should be fluf...

Page 23: ...on Box 120 VAC Line WHITE GREEN 120 VAC RTN MODEL DS2070S SYNETEK CONTROLS INC MAIN VALVE RTN BLACK GROUND 120 VAC RTN 120 VAC HOT MAIN VALVE GREEN BLACK WHITE RED BLACK RED White Rodgers 120 Volt Valves Inlet Gas BLACK RED 1 2 4 3 High Voltage Lead T203 White rodgers valve wiring 12 15 03 djt T203 Fig 40 Electronic ignition module wiring diagram ...

Page 24: ...ier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions To Turn Off Gas to Heater Lighting and Operating Instructions 1 Set thermostat to lowest setting 2 Turn off all electric power to...

Page 25: ...ween black hot If 120V not present check fuse or circuit breaker turned to ON and reset line at control module and white or repair wiring leading to fireplace cycle has been return at module completed Spark for six 6 seconds a Check that gas is turned on Turn gas on and or purge system at Ignitor but no ignition system purged of burner b Check that tips of ignitor are Position elecrodes so tips are...

Page 26: ... of fireplace close to gas valve Installer Notice These instructions must be left with the appliance Instructions for converting your fireplace from Natural gas to Propane LP gas All fireplaces are shipped from the factory equipped to operate on Natural gas To convert the fireplace to op erate on Propane LP gas follow the instructions below Please see the appropriate parts list for your model for part...

Page 27: ...est for gas leaks 4 Relight the main burners and verify proper burner ignition and operation 5 Check the air shutter opening for the corresponding gas used 6 With the main burner burning read the pressure on the manometer or pressure gauge The pressure on the gauge should read between 9 8 and 10 2 w c 7 Turn off the gas supply Turn off the electrical supply to the appliance 8 Remove the manometer ...

Page 28: ...Pressure inches w c Normal HI Normal Low Natural Gas 3 5 1 6 LP Propane 10 0 6 3 High Altitude When installing this fireplace at an elevation between 0 and 2000 feet 0 610m in the USA and 0 and 4500 feet 0 1370m in Canada the input rating does not need to be reduced When installing this fireplace at an elevation above 2 000 feet in the United States it may be necessary to decrease the input rating b...

Page 29: ...s contact your near est dealer to get the appliance serviced Alternatively the appliance can be cleaned by removing all the logs Handle the logs gently so as not to damage them Always lift each log by holding it carefully at each end Maintenance After the logs are removed allowing access to the burn er area use a vacuum cleaner to carefully remove dust and loose particles from the base logs and fr...

Page 30: ...ng T203 Air shutter 12 12 03 djt T203 Opening A Fig 45 Air shutter opening Normal and High Direct Vent Units Inputs Orifice Size Altitude BTU Hr Manifold Pressure Orifice 0 2000ft Altitude in USA Model Max Input Max Orifice 0 4500ft Altitude in Canada 33TDVDSN 18 000 3 5 w c 079 33TDVDSP 18 000 10 0 w c 56 DMS 36TDVDSN 20 000 3 5 w c 45 DMS 36TDVDSP 20 000 10 0 w c 55 DMS 39TDVDSN 22 000 3 5 w c 43 D...

Page 31: ...notice TDVDSN TDVDSP Series Gas Fireplace Units GF1HT1 GF1HT2 GF1HT3 Ref Description 33TDVDSN 36TDVDSN 39TDVDSN 1 Log Set complete 20008173 20007629 20007629 1a Log Front 20008190 76895 76895 1b Log Back 20007630 20007630 20007630 1c Log Top Right Twig 75318 75318 75318 1d Log Top Left Twig 75319 75319 75319 2 Lava Rock Package 1lb Bag 10001454 10001454 10001454 3 Embers Platinum 78037 78037 78037...

Page 32: ...own 51865 51865 51865 15 Fan Temperature Sensor FK24 Option not shown 51704 51704 51704 16 Fan Speed Control FK24 Option not shown 51738 51738 51738 17 Knob Fan Speed Control FK24 Option not shown 51882 51882 51882 18 Fan Assembly FK12 Option ZA15110 ZA1110 ZA1110 19 Glass Door Assy 20011627 20011628 20011629 20 Clamp Window Frame Assembly 54174 54174 54174 21 Top Louvre Assembly 10000292 10000037...

Page 33: ...nveniently located wall socket Method B Using EB 1 Receptacle Box The EB 1 receptacle box Pt ZA1200 may be hard wired into the house supply The fan lead is then plugged into the EB 1 box For instruction on wiring the EB 1 Electrical Junction Box see the earlier chapter in the Installation section of this manual FK12 Fan Assembly This auxiliary fan system increases the efficiency of the circulation ...

Page 34: ...d electrician Wiring Instructions Black White Ground FP394 WIRING DIAGRAM 11 20 96 Fan Temperature Sensor Speed Control FP1025 Fig 47 FK24 fan wiring Ceramic refractory panels are available in kit form for the RDV TDV series appliances 5 Place the rear refractory panel in place 6 Slide the side refractory panels into place to hold the rear panel secure Adjust the top adjustable tabs to hold the si...

Page 35: ... top louvre from fireplace by lifting up and pulling out 3 Hang Bay Window Screen Frame Assembly over top of existing window frame assembly FP1234 Bay window 11 02 Top Louvre Bay Window Frame Ceramic Refractory Ceramic Refractory Screws Bottom Brass Trim Bottom Louvre As semblies FP1234 Fig 49 Bay window installation CFM178 Bay Window Screen 8 17 01 sta CFM178 Fig 50 Bay window screen assembly Opti...

Page 36: ...hed Alteration of the Product in any way is prohibited and voids any and all war ranties Removal of the date plate alters the Product and voids the warranty The installer must have completed the Installation and Startup Checklist a copy of which must be sub Model Number ____________________ Serial Number _____________________ Date of Installation ____ ____ ____ Purchased From ___________________ m...

Page 37: ...e size adequate for input rating BTU s per hour of fireplace per National Fuel Gas Code NFPA54 in the case of USA installations or Installation Code CAN 1 149 in the case of Canadian installations Make following checks Gas line integrity at supply line connection Glass front panel position Correct gas pressure Inlet Pressure __________ inches w c Manifold Pressure __________ inchesw c Piezo ignitor...

Page 38: ...ze adequate for input rating BTU s per hour of fireplace per National Fuel Gas Code NFPA54 in the case of USA installations or Installation Code CAN 1 149 in the case of Canadian installations Make following checks Gas line integrity at supply line connection Glass front panel position Correct gas pressure Inlet Pressure __________ inches WC Manifold Pressure __________ inchesWC Piezo ignitor funct...

Page 39: ... dotted line To register your warranty please provide the information indicated on this form and mail it to TEMCO Fireplace Products Attn Warranty Registration 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Model ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper install...

Page 40: ...el EnerGuide Ratings Fireplace Efficiency 33TDVDSN 57 9 33TDVDSP 57 9 36TDVDSN 58 51 36TDVDSP 58 51 39TDVDSN 65 39TDVDSP 65 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...

Reviews: