DEOXEASY quick reference rev 1.1 29/06/16
pag.
1
DE-OX
®
EASY
OXYGEN AND HELIUM
ANALYZER
Quick reference guide:
Warning
Please refer to the complete manual in electronic format before operating the instrument. This guide is just a
quick support. Misuse of this instrument may lead to death.
For switching on the instrument, keep pressed the
ON/OFF key for few seconds. The analyser is calibrated
as per the last calibration done (default is 21.0%).
The analyser will display alternatively O2 and the oxygen
reading.
Pressing the ON/OFF key the instrument will display
alternatively He and the helium reading.
For analyzing connect the sensor to the gas source at 0,5-
1 lit/min and 1 bar.
Pressing the CALIB key it is displayed the Volt ouput of the
battery (Bat), the oxygen sensor mVolt output (SnS) and
the helium sensor mVolt output.
Pressing the PROG key you will go to the programming
oxygen calibration point and the auto switch off.
Calibration Point (cPt) sets the oxygen calibration point.
Auto Switch Off Delay Time (t00) sets the switching off
delay time in seconds. At 000 the instrument will not
automatically switch off. Default value is 180 sec.
For changing the value into any programming page press
PROG^ key.
For going to the next value press CALIB< key.
For saving the value and going to the next program page press ON/OFF key. At the end of the programming pages is
displayed End.
For calibrating with a know sample gas (such as air 21.0), set that value in the Calibration Point of programming
page and exit the programming pages (pressing ON/OFF key). Flow the sample gas on the sensor for at least 1
minute or when the value reading is stable. Then press at the same time ON/OFF and CALIB keys.
For resetting the instrument to the original factory settings (rES), power on the instrument pressing at the same
time for few seconds the ON/OFF and the <CALIB keys. The instrument will lose all the previous calibration for
going to the original factory settings.
For switching off the instrument keep pressed the ON/OFF key for few seconds.
For replacing the battery or the sensor, unscrew the four screws on the panel, open the instrument, replace the
battery or sensor with a new one, close the instrument screwing the four screws.
TEMC
®
Via Donna Prassede 5 A
I-20142 MILANO ITALY
Phone +39 02 8463648 or +39 080 4490264
E-Mail: [email protected] Website: www.temc.it
DE-OX
®
EASY
ANALIZZATORE DI OSSIGENO E ELIO
Guida veloce di riferimento:
Attenzione
Fare sempre riferimento al manuale completo in formato elettronico prima di utilizzare lo strumento. Questa
guida è un e veloce supporto all’uso ma non è completa. L’uso non corretto di questo strumento può
provocare la morte.