background image

 

 

 

 

 
 

 

 

 

 
 
 
 

AD615/S 

Analog/Digital Encoder 

for Multicast Audio Streaming  

 

 
 

 
 
 
 
 
 
 
 
 
 
 

Audio Over IP Network Series 

 
 
 
 
 
 
 
 
 

PRODUCT MANUAL 

 

Version HW 1.0 - Version SW 1.09m 

 
 

 
 
 
 

Revision 

Date 

Revision reason 

Prepared 

Checked/Approved 

02/11/2017 

Update 

MM, DP 

DP, FL 

TEMA TELECOMUNICAZIONI 

 

“IP COMMUNICATION AND SECURITY COMPANY” 

 

WWW.TEMATLC.IT 

 

Products for VoIP SIP LAN networking Communications, Paging Amplifiers Systems and 
Audio  Applications.  Zone  Announcements,  Night  Ringer,  Multicast  general  call, 
Background music, Standard SIP call or Emergency call, SD  memory with  pre-recorded 
messages, Relays for LAN drives. 

Summary of Contents for AD615/S

Page 1: ... Approved 0 02 11 2017 Update MM DP DP FL TEMA TELECOMUNICAZIONI IP COMMUNICATION AND SECURITY COMPANY WWW TEMATLC IT Products for VoIP SIP LAN networking Communications Paging Amplifiers Systems and Audio Applications Zone Announcements Night Ringer Multicast general call Background music Standard SIP call or Emergency call SD memory with pre recorded messages Relays for LAN drives ...

Page 2: ... CONFORMITÀ CE DECLARATION OF CONFORMITY CE The crossed out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in an unsorted municipal waste in order to provide for the treatment of WEEE Waste Electrical and Electronic Equipment using best available recovery and recycling techniques Specific treatment for WEEE is indispens...

Page 3: ...al specifications at any time and without any notice 6 Products powered via PoE Power over Ethernet may only be connected with cables coming from the internal network company inside the building are not allowed connections LAN cables coming from outside the building 7 Use for this device only and exclusively original spare parts and consumables supplied by Tema Telecomunicazioni The company is not...

Page 4: ...O STREAMING 11 7 INSTALLATION 12 7 1 MOUNTING AND SYSTEM POSITIONING 12 7 2 CONNECTION 12 8 PROGRAMMING 14 8 1 PREPARATION FOR THE SYSTEM PARAMETERS PROGRAMMING 14 8 2 ACCESS TO PROGRAMMING 15 8 3 NETWORK PARAMETERS 16 8 4 SIP PARAMETERS 16 8 5 GENERAL PARAMETERS 17 8 6 CALL BUTTONS 18 9 MAINTENANCE 19 9 1 SYSTEM 19 9 2 LOGIN CREDENTIALS 20 9 3 DIAGNOSTIC LOGS 20 10 APPENDIXES 21 10 1 APPENDX 1 US...

Page 5: ...eneral call on all AD600 series amplifiers and IP speakers connected to the network Audio Streaming Codec AD615 S offers the possibility to choose the most appropriate codec according to the audio quality and the required LAN bandwidth The following codecs are available G711 a µ law G722 16kHz 24kHz 32kHz Proprietary Linear for the highest audio quality Multicast Streaming Audio for music and anno...

Page 6: ...ling mount AA 39DL Plug Power Supply 220Vac 12Vdc 1 0A AA 39D1A DIN Power Supply 220Vac 15Vdc 1 0A AA 39P4 PoE injector 230Vac 48Vdc 0 5A AA 39E3 E6V DIN Power Supplies 220Vac 24Vdc 1 5A 220Vac 24Vdc 2 5A AA 36 Protected Power Relay Actuator 250Vac 16A 4KVA command in AC DC 12V 24V 1 contact Led contacts protected by electric arcs Ideal for driving loads up to 4 000W AD612 IP SIP PoE 40W 2x20W Amp...

Page 7: ... 3 position switch lever to enable disable LAN sending of digitized signal Selectable codecs G711 G722 Linear 16kHz 24kHz 32kHz Power supply via PoE Power over Ethernet or external power supply at the same time Programming via the Web Interface with password protection Possibility of software firmware update via LAN Integration with the local LAN 100BaseT Ethernet LAN port with RJ45 connector Inte...

Page 8: ...2 0 RFC 3261 Audio communication Monodirectional from AD615 S to receiver devices Bandwidth 80Hz 20kHz RTP Multicast audio Streaming G 711 a µ Law G 722 Linear 16kHz 24kHz 32kHz External audio input Stereo 3 5 mm stereo jack connector Isolation via internal system transformer maximum signal level impedance of 2Vpp 600 Ohm Microphone input Proprietary connector RJ45 Electret microphone with power s...

Page 9: ...received directly from the microphone connected to the system on the proprietary RJ45 connector eg short operator announcements will be transmitted With the optional microphone base the operator who has to launch warning messages will operate directly on the table microphone base and no longer by the AD615 S system lever The microphone output volume is easily adjustable with a trimmer located on t...

Page 10: ...irectly from AD615 S note that it is not a Phantom power suitable for commercially available microphones then it is necessary to have the accessories provided by Tema for generating announcements messages To broadcast the message which AD615 S will send on the second address channel that has priority over music it is necessary to move the system lever down and keep it in this position for the dura...

Page 11: ... base to another priority channel over the music channel Example In a plant there are the systems showed in the diagram connected to the same network switch AD615 S can make an announcement via Multicast to the address 239 255 12 42 or normally broadcast ambient music at 239 255 12 43 Many more devices than those shown in the example may be connected there are no limits The receivers are programme...

Page 12: ...terminal block Vout Terminal block from which it is possible to withdraw unregulated power supply POSITIVE GND Terminal block from which it is possible to withdraw unregulated power supply NEGATIVE A Terminal block to power the system irrelevant polarity C Terminal block to power the system irrelevant polarity RJ45 LAN Port AD615 S requires a LAN cable to connect to the network If the port cable h...

Page 13: ...ansmission is selected from either of the two ports Wall installation with dowels Use the anchors provided and before fixing to the wall fold the flaps with eyelet not used towards the side walls of the device Installation on standard DIN rail Secure the plastic DIN accessory on the back of the device using the 2 flat washers 2 countersink 2 5x6mm screws supplied and clip onto a standard DIN rail ...

Page 14: ... click on it and it will appear the window where it is necessary to click on the Properties button It will then open the window where must be selected Internet Protocol Version 4 TCP IPv4 and then click the Properties button again See the following figures If the PC is already on subnet 192 168 0 x with a mask 255 255 255 0 ignore the following steps Otherwise proceed as follows The address of the...

Page 15: ...ple and intuitive it is always visible on the left the menu for selecting the functions to be programmed while on the right is shown the configuration window that is currently active Any change will be confirmed by pressing the Apply or Save buttons Closing the browser or changing the page without selecting those buttons will make lost any change Any changes do not require restarting the device ex...

Page 16: ...network segment of your computer so that it can connect to the new address IP address specify the IP address you want to assign to AD615 S Subnet mask indicate the subnet mask to be assigned to AD615 S Default gateway indicate the gateway that can enable AD615 S to access to internet Primary and secondary DNS server indicate the addresses of two DNS servers you want to use to resolve IP addresses ...

Page 17: ...nput digitized audio signal The parameter also set the codec that will automatically use the AD600 series devices into the network In the receiving devices it is not necessary to program the codec type set into AD615 S since the detection will be automatic The rest of the fields are ignored by AD615 S It is possible to choose between G711 the lowest quality and L16 at 32kHz the highest quality Obv...

Page 18: ...crophone In the DAY field of button 1 you have to program the destination of the audio stream associated with the high position of the lever generally the music in the DAY field of button 2 you should instead program the destination of the audio associated with the low position of the lever announcements from the microphone The two stream addresses may also coincide In the First number field enter...

Page 19: ... TEMA using the Browse Update Once you ve uploaded the new version the device must be restarted License enter in this field the license key to activate any additional services such as the use of messages over 16 seconds Backup and restore it is possible to save the current settings to restore them in case of a programming error or device replacement Reset to factory settings all settings are lost ...

Page 20: ...he login credentials The password must be entered twice for confirmation 9 3 Diagnostic logs To identify small configuration problems it is possible to activate a diagnostic summary on the activity of the two VoIP channels of the device Simply connect via TCP port 9991 with Telnet or a terminal like Hyperterminal It is also possible to view the history of activities for each module by clicking Las...

Page 21: ...ble on a programmed Multicast channel All AD600 listening receiving systems on that particular Multicast channel will broadcast this audio To do this follow these steps 1 Download the VLC program and install it on your Windows PC the folder where the VLC program is installed is located under C programmi x86 VideoLAN 2 Record or obtain an audio file 3 From the program window select the file to play...

Page 22: ...the wires some additional millimeter Hold with one hand the wires and with the other pull the smoothing sheath Straighten the wires previously individually pair twisted Compose the color sequence following the pattern Level the length of the cables into place Insert the tightened wires into RJ45 connector holding them between your fingers until they are channeled into the guides inside the connect...

Page 23: ...TEMA TELECOMUNICAZIONI IP PoE Multicast Encoder AD615 S MAS AD615 S REV00EN Page 23 of 23 Notes ...

Reviews: