Indicators and Diagnostics
Page 4-12
Troubleshooting Outgoing Calls
NET-PATH does not go off-hook.
Possible Cause:
•
Incorrect database. Event is not programmed, is not programmed correctly, cur-
rent time is not in the Action window, or event duration is too long.
•
No App loaded.
Incoming calls are not received at the Polling and Analysis Center.
Possible Cause:
•
Bad database. Incorrect telephone number.
•
Modem at the receiving end is not set for auto-answer.
•
Restricted telephone line. Contact your local telephone representative.
Call was received at the Polling and Analysis Center, but did not have a carrier.
Possible Cause:
•
Non-compatible or defective modem at the Polling and Analysis Center.
•
The modem at Polling and Analysis Center is not in data mode.
•
You selected an incorrect database option.
Call received at Polling and Analysis Center, modem connected, but message not
received.
Possible Cause:
•
Bad database. Incorrect protocol flag.
•
Bad telephone line. Contact your local telephone representative.
•
Incorrect receiving option (parity, speed, stop bits, data bits)
Summary of Contents for SEB NET-PATH
Page 1: ...SEB NET PATH Installation and Operation Guide ...
Page 2: ......
Page 3: ...SEB NET PATH Installation and Operation Guide ...
Page 6: ......
Page 18: ...Preface xii Notes ...
Page 24: ...Description and Specifications Page 1 6 Notes ...
Page 42: ...Installation Page 2 18 Notes ...
Page 58: ...Operation Page 3 16 Note ...
Page 80: ...Index I 4 Notes ...
Page 81: ......