TELTRON Clean-Q User Manual Download Page 1

HYGIENE MONITOR SYSTEM

Clean-

Q

 

User Manual

TELTRON INC.

TEL : +82-42-360-2012  FAX : +82-42-360-2010  E-mail : [email protected]

Summary of Contents for Clean-Q

Page 1: ...HYGIENE MONITOR SYSTEM Clean Q User Manual TELTRON INC TEL 82 42 360 2012 FAX 82 42 360 2010 E mail teltron teltron com...

Page 2: ...order to use Clean Q Please inquire purchase department 4 When you measure after inserting Q tube let Claen Q stand vertically 5 As both harmful and harmless microbes can be measured it may not correc...

Page 3: ...r 4 How To Setup Clean Q 9 4 1 Previous Record List 4 2 Time Setup 4 3 Connecting to PC 4 4 Lighting Setup 4 5 Sound Setup 4 6 Auto Shutoff Setup 5 Error Message while Clean Q runs 11 6 How To Use PC...

Page 4: ...es unlimited measurements from time and space The guideline value for contamination degree is served and the decision result is shown on screen as safety caution or contamination Measured item can be...

Page 5: ...2 Structure of Clean Q 2 1 Components in box Clean Q components in box Clean Q terminal 1ea Terminal pouch 1ea PC program CD 1ea USB cable 1ea AA alkaline battery 2ea User s manual 1ea 4...

Page 6: ...eries after this cover open Product information Be attached a sticker with product information USB port inside cover connect to PC with USB cable in order to transfer data Q tube inlet inside cover In...

Page 7: ...ccurs continuously please call to TELTRON sercenter Ignore Ignore and go to next stepTELTRON does not guarantee the performances of Clean Q in case of choosing Ignore 3 2 Preparation Once system check...

Page 8: ...talling PC Sync program in enclosed CD on PC Refer 6 Clean Q PC program usage Use no measured target mode if you do not need 3 3 Measurement Wipe measuring place with area of about 10 cm x 10 cm evenl...

Page 9: ...he solution at the upper part can run down well Shake Q tube during 10 seconds so as reagent to react well with measured Start message appears after 10 seconds If Start message appears insert Q tube i...

Page 10: ...of safety caution or contamination It is recommended value and not absolute one Safety It means measured target is safe on the basis of the guideline provided by TELTRON 0 No ATP was detected from me...

Page 11: ...it is not reset even after removing AA batteries due to internal battery Increase time Move Next Move Previous Exit without Saving 4 3 PC Connection Connecting between terminal and PC 4 4 Lighting Set...

Page 12: ...Setup Initialization Use when you wish to bring user and target information to the initial state Once setup initialization is executed user and target names which user have changed become initialized...

Page 13: ...t Q tube Please request TELTRON s service center 6 How To Use PC Program of Clean Q 6 1 Confirmation after selecting 5 PC Connection If OK button is pressed after selecting 5 PC Connection the followi...

Page 14: ...llowing window is displayed after executing Clean Q_Sync_Manager 6 4 Communication port connection Check communication port number in order to connect terminal to PC Follow below figures step by step...

Page 15: ...2 Double click System 3 Click Hardware and Device Manager 4 Check COM port number of USB Serial Port 14...

Page 16: ...button in order to import user information guideline and measured result Data importing completed 6 6 Save measured data to excel file Open save window by click Save to CSV file button Set directory...

Page 17: ...Delete saved measured records in order to add user information Click Delete all and Reset Type in ID and Name and Click Add Click Save to Clean Q after adding user information is completed 16...

Page 18: ...ld be deleted when deleting user and reference information Measured records are saved based on user and guideline informations If user and guideline informations are changed by user saved results are...

Page 19: ...t TELTRON service engineer 9 Due to natural disasters lightning fire earthquake flood damage tsunami etc How to use simply 1 Turn on the terminal by pressing during two seconds 2 Confirm whether there...

Page 20: ...TELTRON INC 305 343 ITplex 202 26 41 Gajeongbuk Ro Yuseong Gu Daejeon Korea TEL 82 42 360 2012 FAX 82 42 360 2010 E mail teltron teltron com URL www teltron com...