93
13.7
Crash Detection Scenario
Scenario is activated when Crash is detected by device using accelartaion values
13.7.1
Configuration
Figure 76 Crash detection configuration parameters
Crash detecion
: Scenario Enable or Disable
Acceleration threshold:
Acceleration values, Scenario is activated if configured value
exceeds
Acceleration duration:
Duration of acceleration for scenario activation
13.8
COM1 and COM2 Working Modes
COM1 and Com2 are used to connect external devices.
13.8.1
Silent Mode
FMB630 doesn't do any activity in silent mode. Logs aren’t saved and any data isn’t sent.
13.8.2
FM Log Mode
This is default mode of the FMB630. It is suitable for debugging.
13.8.3
LLS Mode
This mode is suitable for LLS sensors.
13.8.3.1
LLS Mode Configuration
1.
Globals->COM2 Settings->Baudrate = 19200
2.
Globals->COM2 Settings->Mode = LLS
Note
On Valid data Receive Status LED will blink.
13.8.4
LCD Mode Configuration
1.
External Devices->COM2 Settings->Baudrate = 57600
2.
External Devices ->COM2 Settings->Mode = LCD
How to use:
* From Terminal need send command "WT^W your text here"