background image

3G Tracking Device Installation Manual

1

2

3

4

5

6

Color

Red

Yellow

Yellow

Black

Purple

Purple

Pin

1

2

3

4

6

5

Pin Name

10-30V DC (+) 

Ignition

1-Wire Data

Ground (-)

1-Wire Power

Digital Output 1

Description

Power supply for module.

Digital input 1

Data channel for Dallas devices 

Ground pin

+ 3,8 V output for 1-Wire®

Digital output. Open collector 

output. Max. 150mA.

Most installations require only the first 3 wires. 

Red

Black

 and 

Yellow

 

(Power, Ground and ignition). Other wires are typically used for additional 

monitoring  

requirements, such as temperature monitoring or Driver ID.

Any un-used wires should ideally be coiled up and kept for potential future 

use, but can be cut if necessary (if cutting, it is our recommendation that at 

least a 3 – 6cm lead be left so as to supply a fly lead for future connection 

of additional monitoring devices).

Reviews: