11
Appendix
11.1
Remote programming of alarm control panels
In this case, the module performs transparent serial data communication over IP connection. The connection
between the programming software and the alarm control panel is provided by the module and an IP Bridge
Virtual Client program.
The module’s serial port is connecting to the alarm control panel while the programming
software is connecting to the virtual serial port created by the client program.
Important!
If you want to access the module via mobile internet, you need to make sure that the APN used by
the computer running the programming software and the APN used by the module are accessible to each
other. If it is possible, the devices have to be connected to the same APN or the mobile network's APN have to
be the part of the computer's network.
11.1.1
Paradox control panel
Installation settings:
Figure 50.
Connect a logic level converter (Paradox 307,306) to the alarm control panel, then connect its serial port output
with the module (see Figure 50. above). Only RX, TX and GND wires will be used, please connect these to the
module in the order shown in Figure 50. above.