tell ecoLINE SIA Installation And Application Manual Download Page 9

 

4  Volume adjusting application 

The  volume  adjusting  application  (Volsetter.exe)  is  availab

le  on  the  manufacturer’s 

website  (

www.tell.hu

).  You  can  use  this  software  to  adjust  the  in-call  volume  levels  if 

necessary and justified. Adjusting may be necessary if voice quality or volume problems 
are experienced, caused by the circumstances in the given place of installation. 

Using the software: 

  Open the Volsetter.exe application. 

  Connect  the  module  to  USB.  The  software  connects  to  the  module  automatically, 

then “

Read

” and “

Set

” buttons become available. 

  Read the actual settings from the module by clicking on 

Read from module

” button. 

 

Mic

 volume: microphone volume (outgoing Contact-ID). 

 

Spk

 volume: speaker volume (incoming HSK/ACK signal). 

  Set  the  desired  volume  level,  then  write  the  settings  to  the  module  by  clicking  on 

Set

” button. 

Attention!  Even  minor  level  adjustment  result  significant  changes  in  the  in-call 
volume,  therefore  it  is  recommended  to  make  slight  changes  in  the  appropriate 
direction and then check the voice quality again and test the communication! 

  The new settings are applied after writing, in the very next voice call.  

 

Summary of Contents for ecoLINE SIA

Page 1: ...ecoLINE SIA IP Adapter INSTALLATION AND APPLICATION MANUAL for module version v5 02 and higher Rev 1 6 15 09 2015...

Page 2: ...for backup GSM call 5 3 1 6 Modification of the settings by SMS 6 3 1 7 Incoming SMS message forwarding 6 3 2 Configuring by SMS commands 6 4 Volume adjusting application 9 5 Module status 10 5 1 LED...

Page 3: ...iguring the communication protocol is not necessary 2 Functions Converting Contact ID format and event reporting in SIA IP format Supports receiver side static IP and domain as well Backup Contact ID...

Page 4: ...Windows XP SP2 Windows 7 32 64 bit Windows 8 x 32 64 bit Windows 10 32 64 bit Using the programming software the following parameters can be configured 3 1 1 GPRS settings APN name access point name...

Page 5: ...is option cannot be changed Estimated data traffic indicates the estimated monthly data traffic according to the configured supervision test report sending frequency ATTENTION THE INDICATED ESTIMATED...

Page 6: ...RUSER The module sets the sender s phone number as Superuser The module accepts this command only if no Superuser has been set yet SU Deletes the current Superuser phone number The module accepts this...

Page 7: ...raffic counter The value in the response message is specified in Bytes GMIC X Adjusts the microphone volume outgoing Contact ID volume Substitute X with a number between 0 15 Default setting 3 GSPK X...

Page 8: ...nfigure the first number dialed by the alarm control panel e g 1111 assigned to the first IP address e g 111 112 113 114 with port number e g 9999 send the following SMS message to the module s phone...

Page 9: ...e connects to the module automatically then Read and Set buttons become available Read the actual settings from the module by clicking on Read from module button Mic volume microphone volume outgoing...

Page 10: ...hardware Firmware version version of the firmware System timer Date time internal timer of the connected module Uptime elapsed time since the latest module restart GSM status GSM signal current GSM si...

Page 11: ...ems or and wave interference fading use another directed type of antenna or find a more suitable place for the module 6 2 Putting into operation Disable PIN code request voicemail and missed call noti...

Page 12: ...Transmission frequency GSM 900 1800 MHz 850 1900 MHz GSM phone type Simcom SIM900 Dimensions 100 x 70 x 19mm Weight 80g packed 100g 7 2 Generated phone line specification Line voltage 48 V Line curren...