![Telit Wireless Solutions LE910C1 Series Hardware User'S Manual Download Page 22](http://html1.mh-extra.com/html/telit-wireless-solutions/le910c1-series/le910c1-series_hardware-users-manual_1083683022.webp)
LE910C1
Hardware User Guide
1VV0301298 Rev. 1.08 - 2017-11-14
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA
Page
22 of 119
2.5.
Environmental Requirements
2.5.1.
Temperature Range
Operating
temperature range
-20 ~ +55°C.
This range is defined by 3GPP (the global standard for wireless mobile
communication). Telit guarantees its modules to comply with all the
3GPP requirements and to have full functionality of the module with
in this range.
-40 ~ +85°C.
Telit guarantees full functionality within this range as well. However,
there may possibly be some performance deviations in this extended
range relative to 3GPP requirements, which means that some RF
parameters may deviate from the 3GPP specification in the order of a
few dB. For example: receiver sensitivity or maximum output power
may be slightly degraded.
Even so, all the functionalities, such as call connection, SMS, USB
communication, UART activation etc., will be maintained, and the
effect of such degradations will not lead to malfunction.
Storage and non-
operating
temperature range
–40°C ~ +85°C
2.5.2.
RoHS Compliance
As a part of the Telit corporate policy of environmental protection, the LE910C1 complies with the
RoHS (Restriction of Hazardous Substances) directive of the European Union (EU directive
2011/65/EU).