background image

 

Telit GE864 and GC864

Product Description

80273ST10008A Rev. 3 - 10/02/06

 

 

Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved 

page 64 of 72

 

6.1 GE864-QUAD Conformity Assessment 

 

 
 

Summary of Contents for GC864 Series

Page 1: ...AI Telecom written authorization All Right reserved Right of modification reserved page 1 of 72 T Te el li it t G GE E8 86 64 4 Q QU UA AD D G GE E8 86 64 4 P PY Y G GC C8 86 64 4 Q QU UA AD D G GC C8...

Page 2: ...bidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 2 of 72 This document is relating to the following products Model P N GE864 QUAD 3990250651 GE86...

Page 3: ...functional 11 2 3 3 RoHS compliance 11 2 4 Operating Frequency 11 2 5 Transmitter output power 12 2 6 Reference sensitivity 12 2 7 Antenna 12 2 7 1 GC864 Antenna connector 13 2 8 SIM card holder supp...

Page 4: ...er output 19 2 16 Audio levels specifications 20 2 17 Camera compatibility EASY CAMERA 21 2 18 Converters 21 2 18 1 ADC Converter 21 2 18 2 DAC Converter 21 2 19 Board to Board interface 23 2 19 1 GE8...

Page 5: ...utgoing connection 47 5 1 3 1 Configuring the GPRS access 48 5 1 3 2 Configuring the embedded TCP IP stack 48 5 1 3 3 Defining the Internet peer to be contacted 48 5 1 3 4 Request the GPRS context to...

Page 6: ...vailable Notwithstanding the foregoing Telit Communications S p A does not make any warranty as to the information contained herein and does not accept any liability for any injury loss or damage of a...

Page 7: ...all state of the art features like GPRS Class 10 Voice Circuit Switched Data transfer Fax Phonebook and SMS support EASY GPRS embedded TCP IP stack and EASY CAMERA external camera support and battery...

Page 8: ...ingent requirements Telit supports its customers with a dedicated Support Policy with Telit Evaluation Kit EVK2 to help you develop you application A Website with all updated information available an...

Page 9: ...06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 9 of 72 2 General Product Description 2 1 Size 2 1 1 GE864 The Telit GE864 mo...

Page 10: ...ev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 10 of 72 2 1 2 GC864 The Telit GC864 module overall dimensions are...

Page 11: ...85 C 30 C 85 C Temperature exceeding the range of normal operating conditions can affect the sensitivity the performance and the MTBF of the module 2 3 2 Vibration Test non functional 10 12Hz ASD 1 9...

Page 12: ...2 6 Reference sensitivity GSM 850 900 The sensitivity of the Telit GE864 and GC864 modules according to the specifications for the class 4 GSM 850 900 portable terminals are 107 dBm typical in normal...

Page 13: ...final position is being defined and will be known soon 2 9 Supply voltage The external power supply must be connected to VBATT signal and must fulfill the following requirements Nominal operating vol...

Page 14: ...ry must always be connected to the VBATT pin of the GE864 GC864 2 12 User Interface The user interface is managed by AT commands specified on the ITU T V 250 GSM 07 07 and 07 05 specifications 2 12 1...

Page 15: ...it GE864 and GC864 support GPRS Class 10 MS Class B CSD up to 14 4 Kbps Fax service Class 1 Group 3 2 12 6 Local security management With lock of Subscriber Identity module SIM and security code reque...

Page 16: ...ot registered turning off slow blinking period 3s Ton 0 3s Registered full service Permanently on a call is active 2 12 13 Automatic answer Voice Data or FAX After a specified number of rings the modu...

Page 17: ...sequences dedicated investigations on the parameter settings have to be made 2 12 17 Buzzer output The General Purpose I O pin GPIO7 can be configured to output the BUZZER output signal with only an e...

Page 18: ...4 and GC864 Whenever this signal is pulled low the GE864 GC864 is reset When the device is reset it stops any operation and after the release of the reset it shuts down without doing any detach operat...

Page 19: ...lockout functions 2 14 RTC Bypass out The VRTC signal brings out the Real Time Clock supply which is separate from the rest of the digital part allowing having only RTC going on when all the other pa...

Page 20: ...use For more information on the audio refer to the Hardware User Guide The following table reports all the audio level specifications Microphone characteristics Internal audio mic input External audio...

Page 21: ...and GPIOs Signal GE864 ball GC864 pin CAM_SDA D7 36 CAM_SCL C6 35 CAM_CLK F8 44 CAM_ON K11 67 CAM_RST C9 76 When the camera is activated then these pins are not accessible as GPIO The AT commands of t...

Page 22: ...scription 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 22 of 72 Min Max Units Voltage range filt...

Page 23: ...rface C10 SIMCLK O External SIM signal Clock 1 8 3V E9 SIMRST O External SIM signal Reset 1 8 3V D10 SIMIO I O External SIM signal Data I O 1 8 3V C11 SIMIN I External SIM signal Presence active low 4...

Page 24: ...d to L8 PWRMON CMOS 2 8V C2 TGPIO_03 I O Telit GPIO03 Configurable GPIO CMOS 2 8V B3 TGPIO_04 I O Telit GPIO04 Configurable GPIO CMOS 2 8V C3 TGPIO_20 I O Telit GPIO20 Configurable GPIO CMOS 2 8V B4 T...

Page 25: ...J2 VBATT Main power supply Power K2 VBATT Main power supply Power A1 GND Ground Power F1 GND Ground Power H1 GND Ground Power L1 GND Ground Power H2 GND Ground Power L2 GND Ground Power J3 GND Ground...

Page 26: ...2 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 26 of 72 Ball Signal I O Function Internal PULL UP Type B10 B11 B8 A7 A6 A5...

Page 27: ...O_20 VMICN TGPIO_10 GND GND GND 4 TGPIO_14 SIMVCC TGPIO_12 GND Antenna 5 TGPIO_06 ALARM VIBRO_EP VAUX1 TGPIO_23 TGPIO_15 VMICP TGPIO_17 ON_OFF GND 6 C125 RING CAM_SCL IIC_SCL GND TGPIO_02 JDR C106 CTS...

Page 28: ...Type Power Supply 1 VBATT Main power supply Power 2 VBATT Main power supply Power 3 VBATT Main power supply Power 4 VBATT Main power supply Power 5 GND Ground Power 6 GND Ground Power 7 GND Ground Po...

Page 29: ...a carrier detect signal DCD to DTE CMOS 2 8V IIC 35 CAM_SCL IIC_SCL I O Camera IIC interface Configurable GPIO CMOS 2 8V 36 CAM_SDA IIC_SDA I O Camera IIC interface Configurable GPIO CMOS 2 8V DAC and...

Page 30: ...2 8V 68 TGPIO_06 ALARM I O Telit GPIO6 Configurable GPIO ALARM CMOS 2 8V 69 TGPIO_23 I O Reserved to detect ON OFF It is physically connected to pin 49 PWRMON CMOS 2 8V 70 TGPIO_01 I O Telit GPIO1 Co...

Page 31: ...al The Telit GE864 modules has been designed in order to be compliant with a standard lead free SMT process 2 20 2 Module finishing dimensions 2 20 3 Stencil Stencil s apertures layout can be the same...

Page 32: ...ed page 32 of 72 Recommendations for PCB pad dimensions Ball pitch mm 2 5 Solder resist opening diameter A mm 1 150 Metal pad diameter B mm 1 0 05 Placement of microvias not covered by solder resist i...

Page 33: ...rsion Au 3 7 0 05 0 15 good solder ability protection high shear force values The PCB must be able to resist the higher temperatures which are occurring at the lead free process This issue should be d...

Page 34: ...re Min Tsmin Temperature Max Tsmax Time min to max ts 150 C 200 C 60 180 seconds Tsmax to TL Ramp up Rate 3 C second max Time maintained above Temperature TL Time tL 217 C 60 150 seconds Peak Temperat...

Page 35: ...eproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 35 of 72 2 21 Mounting the GC864 on your board The position of the Molex board to...

Page 36: ...ed Right of modification reserved page 36 of 72 2 22 Packing system The Telit GE864 and GC864 are packaged on trays of 20 pieces each This is especially suitable for the GE864 according to SMT process...

Page 37: ...Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 37 of 72 2 22 1 GE864 orientation on the tray The modules on the tray are orient...

Page 38: ...ntation on the tray The GC864 will use the same tray of the GE864 and will be placed with the board to board connector and the shield facing upper The label including the IMEI number will be placed on...

Page 39: ...al RS232 9 pin connector placed on the Evaluation Kit allows the connection of the EVK2 system with a PC or other DTE The development of the applications utilizing the Telit GE864 GC864 module must pr...

Page 40: ...e Evaluation Kit Only one of these power sources can be used at a time and it is selectable with two jumpers For the battery power supply a Li Ion battery charger circuit is provided 3 1 2 Serial inte...

Page 41: ...software tool provided by Telit that runs on Windows based PCs First the program will erase the content of flash memory then the program will write on the flash memory To update the firmware of the mo...

Page 42: ...rved Right of modification reserved page 42 of 72 VII Press OK to the initial message NOTE the power supply must not be disconnected during the firmware update VIII Select the right COM port and speed...

Page 43: ...he application dialogs appear for the GM862 product The GE864 GC864 TFI application will look similar 4 2 Update the GE864 firmware on your interface board In order to allow you to update the GE864 fi...

Page 44: ...scription 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 44 of 72 TX_TRACE Pin 25 RX_TRACE Pin 26...

Page 45: ...to the devices interfacing to the Telit GE864 GC864 module the use of the GPRS and Internet packet service without the need to have an internal TCP IP stack since this function is embedded inside the...

Page 46: ...lated in the previously configured TCP IP packets which will be sent to the other side of the network and vice versa Control plane of ongoing socket connection is deployed internally to the module 5 1...

Page 47: ...he Socket and deactivate the context The connection can be closed because of remote host TCP connection close socket inactivity timeout Terminal Equipment by issuing the escape sequence Network deacti...

Page 48: ...ontacted As last setting definition the host to be contacted and on which port protocol must be set the socket definition see command SKTSET This command permits also to specify the host name instead...

Page 49: ...e data received from the host is serialised and flushed to the Terminal Equipment NOTE this command differently from the AT SKTOP DOES NOT automate all the process of activating the GPRS if no GPRS is...

Page 50: ...ta traffic In data traffic mode Socket Mode SKTM the client can send receive a raw data stream which will be encapsulated in the previously configured TCP IP packets which will be sent to the other si...

Page 51: ...the ACCEPT chain rules of the firewall can induce a connection request the other host requests will be silently discarded without any indication to the remote host for security reasons Once the connec...

Page 52: ...e whole system reliability and functionality and therefore shall be recognized and reported either to the local system for countermeasure actions or to the network providing remote actions An example...

Page 53: ...nsion is aimed at low complexity applications where the application was usually done by a small microcontroller that managed some I O pins and the GE864 PY and GC864 PY through the AT command interfac...

Page 54: ...Copyright c 2001 2002 2003 2004 Python Software Foundation All Rights Reserved All Rights Reserved are retained in Python Permission to use copy modify and distribute this software and its documentat...

Page 55: ...AMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE DATA OR PROFITS WHETHER IN AN ACTION OF CONTRACT NEGLIGENCE OR OTHER TORTIOUS ACTION ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORM...

Page 56: ...flow control is available from Python on this port The GPIO interface allows Python script to handle general purpose input output faster than through AT commands skipping the command parser and going...

Page 57: ...eric Modem Control QUAD PY F Reset base section factory profile configuration F1 Reset full factory profile configuration Z Soft reset FCLASS Select active service class Y Designate a default reset ba...

Page 58: ...t O Return to On Line Mode G Guard tone Modulation control QUAD PY MS Modulation control E Enable disable line quality monitor and auto retrain or fallback fallforward N Operating mode Compression con...

Page 59: ...calls CSSN SS Notification CCUG Closed User Group supplementary service control Mobile Equipment control QUAD PY CPAS Phone activity status CFUN Set phone functionality Power Saving Management CPIN E...

Page 60: ...CMSS Send message from storage CMGW Write message to memory CMGD Delete message Custom AT Commands QUAD PY CGMI Request manufacturer identification CGMM Request model identification CGMR Request revi...

Page 61: ...ort control QUAD PY FLO Select flow control specified by type FPR Select serial port rate FDD Double escape character replacement control Enhanced Easy GPRS custom AT command Definition QUAD PY USERID...

Page 62: ...Scan Extension QUAD PY CSURV Network Survey of the complete 900 1800 1900 Network CSURVC Network Survey in computer friendly format CSURVU Network Survey of user defined 900 1800 1900 chan CSURVUC Net...

Page 63: ...standards GSM Radio Spectrum Standard EN 301 511 and 3GPP 51 010 1 EMC Electromagnetic Compatibility Standards EN 301 489 1 and EN 301 489 7 LVD Low Voltage Directive Standards EN 60 950 In this docu...

Page 64: ...864 Product Description 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 64 of 72 6 1 GE864 QUAD Con...

Page 65: ...Telit GE864 and GC864 Product Description 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 65 of 72...

Page 66: ...Telit GE864 and GC864 Product Description 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 66 of 72...

Page 67: ...Telit GE864 and GC864 Product Description 80273ST10008A Rev 3 10 02 06 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved page 67 of 72...

Page 68: ...Same cautions have to be taken for the SIM checking carefully the instruction for its use Do not insert or remove the SIM when the product is in power saving mode The system integrator is responsible...

Page 69: ...odification reserved page 69 of 72 8 GE864 and GC864 Technical Support Telit s technical support to GE864 and GC864 wireless modems customers consists in Technical documentation available for download...

Page 70: ...ipment DRX Data Receive DSR Data Set Ready DTA Data Terminal Adaptor DTE Data Terminal Equipment DTMF Dual Tone Multi Frequency DTR Data Terminal Ready EMC Electromagnetic Compatibility ETSI European...

Page 71: ...Table PUK PIN Unblocking Code RACH Random Access Channel RLP Radio Link Protocol RMS Root Mean Square RTS Ready To Send RI Ring Indicator SCA Service Center Address SIM Subscriber Identity Module SMD...

Page 72: ...2 3 Environmental requirements changed 2 6 reference sensitivity updated 2 16 Interfaces on GE864 and Pins allocation changed 2 17 with all info regarding the soldering process changed Disclaimer add...

Reviews: