5.5
Power Consumption and Power-Down Modes
5.5.1
Terminal I/O Configuration
The following values are typical power consumption values in the different states.
VSUP = 3,0V, T
amb
= 25°C, all GPIOs open, UART inputs at VSUP or GND, SLCK: 32,768 kHz
Condition
Radio inactive
Note Slow
clock
SLCK
Current Consumption
Unit
I
Avg
Advertising Off, UICP
not active or serial
interface up
internal
Crystal
1,2
1,2
mA
Advertising Off, UICP
active, serial interface
down
(1)
internal
Crystal
9
7
µA
Device in reset
(2)
any
0,44
mA
System off
(1,2)
1,2
µA
(1)
UART-RXD, IUR-IN# and UART-CTS# signals connected to CMOS
high level
(2)
same current consumption w. internal or external slow clock
Table 15: Supply Current Sleep Modes, no Radio Activity