background image

TELIKOU Intercom System

TM-800 Main Station

Instruction Manual

© TELIKOU Systems

All Rights Reserved

Summary of Contents for TM-800

Page 1: ...TELIKOU Intercom System TM 800 Main Station Instruction Manual TELIKOU Systems All Rights Reserved ...

Page 2: ...wing features free of external emission interference stable and reliable performance flexible configuration full duplex communication clear and loud communication sound easy operation and strong noise resistance II Characteristics Remote Microphone kill function RMK IFB function Announcement output Controllable background input Automatic circuit short protection and indication Supports LED working...

Page 3: ...the Mic select switch to select whether the panel microphone or the headset microphone is active 4 Announcement LED ANN LED This LED lights when a announcement function is activated 5 Announcement Button ANN When this button is pressed on microphone signal is sent to ANN Out connector which is at rear panel 6 Call Button Before use call function please turn on the channel which want to talk Turn u...

Page 4: ...hone signal is sent to the intercom channel B When DIP10 is set as ON IFB function is activated Channels 5 8 become four IFB channels Any channel of 5 8 is turned on the channel 1 4 are turned off automatically If Microphone switch Talk is turned on at same time the microphone signal is sent to the IFB channel which is turned on 9 Channel Switch Turn the channel switch handle up or down can monito...

Page 5: ...sing the gooseneck panel microphone along with the speaker or not Use one the following procedures to correctly set the sidetone level controls A Sidetone Adjustment Procedure for Gooseneck Microphone with Speaker turned on 1 Turn on the Mic switch Set Mic select switch to panel 2 Turn the level control to a comfortable level 3 Speak into the microphone while turning the sidetone null control slow...

Page 6: ...s light becomes red under two situations a Called An external call signal is detected b Call When channel 5 8 is turned on press call button LED light lights red and a call signal is sent to the channel 19 Talk LED This LED lights when Talk switch is turned on 20 Remote Mic Kill Switch Microphone on belt pack may forget to be turned off by operators Noise will disturb the whole intercom system The...

Page 7: ... the intercom system is not terminated the level of intercom line will be too high and the system stability will be influenced However only one termination point is allowed within same intercom line If multiple termination points are used incorrectly the driving load will be aggravated and the level of intercom line will be too low This switch is set to ON position by factory default Before using ...

Page 8: ...tance intercom line cable Off disable compensate DIP11 Long line2 On Sidetone compensate for long distance intercom line cable Off disable compensate 29 Program Input The external program signal sent into intercom line through Prog In connector when Program Feed To Switch is turned on The program level can be adjusted by the Program Level Control 14 When Mic Switch 1 is activated this program inpu...

Page 9: ...The standard TELIKOU intercom cable is connected with a pair of 3 pin XLR connectors one male and one female If longer cable is required you can connect several cables together with head end method The wiring of connector is as follows Pin 1 Common Shield Pin 2 Power or Control Signal Pin 3 Audio Signal Notice the pin 1 GND connection for each XLR connector must be insulated from cabinet and canno...

Page 10: ...sed by close proximity of this main station or connected remote stations to power lines or transformers Solution 1 Relocate the offending unit Cause 2 Intercom line cable is not wired properly the shield of microphone cable is not connected to Pin 1 of 3 XLR Solution 2 Check intercom line cable Make sure all the cables Pin 1 of 3 XLR connects correct If this condition occurs it is because the syst...

Page 11: ...TELIKOU TM 800 Eight Channel Main Station 10 HEADSET MICROPHONE Dynamic 200 600 ohm POWER SUPPLY AC 90 260V 50 60Hz 45VA DIMENSION 19 W x1 75 H x9 48 D 482mm x 44 5mm x 241mm WEIGHT 2 6kg ...

Reviews: