Tamper Switch Installation
For all UL/ULC Commercial Burglary Installations, a tamper switch must be wired to monitor the
communicator enclosure. The wiring from the tamper switch assembly to the panel shall be in a rigid
or flexible metal conduit or be supervised along with other wiring from the communicator to the
panel. The tamper switch does not connect to the communicator circuit board.
An easy-attach tamper switch assembly is included with the TG-7 and TG-7A communicator products
and contains installation instructions. If a tamper switch is needed for a TG-7FS or TG-7UB product,
the TG-TAMPER Accessory can be purchased from most Telguard distributors. Note that a tamper
switch is required when using the TG-7FS in a combination fire and burglary system.
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
ALARM PANEL
TRIP
INPUT
EARTH
GROUND
NOTE 2
NOTE 2: UL/ULC BURG NOTE: Tamper
switch should be mounted on the
enclosure and connected to Alarm Panel.
AC
Plug-in
Adapter
Battery
NOTE 1
NOTE 1: Use either AC Power
(from Adapter) with Battery
or use DC Power (from Panel).
NOTE 1
TAMPER
SWITCH