MOSAIQ6 Multi-touch Meter/Analyser
40
Goto: recovers one of the 8 positions
for the antenna that has been previously
stored
-
SCR (only satellite band): Selects the SCR
parameters (multiswitch, standard and
slots) When a slot is enabled (for example
slot 3, freq. 1210MHz), the meter will tune
into the slot frequency (1210MHz) and
will set the slot with the meter parameters:
frequency, band (powering), and DiSEqC.
In addition, a SCR icon will be shown in the
bar at the top (SCR3) to indicate that the
slot is enabled. While the slot is enabled,
all the setting changes of the meter, will
be applied to the currently slot (SCR3).
6.4.10.-IP Analysis (Ethernet Input)
This function makes a deep analysis of the IP signal,
and shows the parameters of the signal and all the
corresponding measures, as well as a chart that
represents a history of the measurements in a
period of time selected by the user.
6.4.10.1.- Main window
IP channel parameters
IP measurements
History of the measurements during an interval
selected by the user. Drag to move the blue mark
6.4.10.2.- Options context menu
•
• Clear: clears the graph.
• Last: 10 min, ½ hour, 1hour, ½ day, 1 day, 1 week.
Allows select the time interval shown in the graph.