EN
15
Remark
:
The bandwidth needed will depend on
the number of services present in the
output (those selected as ON or DCY,
see menu of services).
c. Output Menu
The following standard menu shows the
output
frequency/channel,
the
output level control
and the
output mode control
.
OUTPUT
Freq: 474.00
Level: 99
Output:Norm.
OUTPUT
Ch:C21
(474.000MHz)
Lev:99 Norm.
To modify the frequency, press key until the
desired parametre starts fl ashing. Then you can
change its value by means of keys and .
The output frequency range is 46 to 862 MHz
The output level control allows values between 00
and 99.
The available output values are:
•
Norm
Normal Output Mode
•
CW
Continuous Wave Mode. A continuous
carrier is generated in the output
frequency selected (useful for balancing
the headend in the absence of an input
signal).
•
OFF
No output is generated.
•
NULL
QAM output modulation with null
packets
only.
d. Services menu
This menu shows the list of
transport stream
services selected. Each time the user selects a new
input transport stream, the unit performs a search
for services.
During the process, the unit will show the message
below displaying the number of channels as soon
as they are being found:
SERVICE
Scanning: 13
Once the search has completed, a list of services is
displayed with the following information:
SERV 10125
2/8 18/25
La 2
OFF
It is indicated the service order number as well
as the total number of services in the
multiplex
(the fi gure indicates that the 2nd service out of
8 services, is available), the statistics (18/25) and
the service name. In the processing mode (see
Confi guration menu 2) it is shown if the user has
selected it to: either
remove
its encryption from
the output (OFF) by means of a module CAM (DCY),
or to
pass through
without modifi cation (ON).
Statistics information is the following:
fi rst
number
indicates the percentage of the output
occupied by the displayed service;
second
number
indicates the free percentage at the
output.
In the example:
• Service “La2” would occupy the 18% of the
output (since it is set OFF, means that it is being
eliminated)
• There is a 25% of free room.
• So we can easily see that, in principle, this
service could be activated (ON or DCY), since
there is still suffi
cient capacity at the output.
The free capacity percentage at the output is
only updated once recorded the confi guration
of services.