PRISM Field Upgrade Kit Instructions
25
Verify the hardware upgrade
Table 3: Required equipment
Test equipment
Requirements
Example
Video test signal generator
HD 1080 59.94i
Telestream TG8000 with
■
100% color bars
SDI7 module
75 Ω coaxial cables
RG-6 type coaxial cable with
male 75 Ω BNC connectors,
1 to 2 m long, suitable for
use to 6000 MHz.
1694A. Telestream
part number 012-
0159-01.
Computer monitor and cable
(for use with MPX)
Any standard 1080-capable
monitor with Display Port
connector and cable.
Mouse with USB interface
(for use with MPX)
Any standard USB computer
mouse
1.
Apply power to the instrument.
2.
MPX only: Connect the external display.
3.
Connect the TG8000 SDI7 module output to the SDI 1 IN input on the
PRISM monitor.
4.
Set the SDI7 module to HD 1080 59.94i format using the following steps:
a.
On the TG8000, push the front-panel
MODULE
button until the
SDI7 module main menu appears.
b.
Push the down (▼) arrow
button to access the output mode menu.
c.
Use the left (◄) or right (►) arrow button to scroll through the available
output modes.
d.
Select the HD output and push the
ENTER
button.
NOTE.
The dot will appear in front of the output mode on the display, to
indicate that it is now the selected output mode.
e.
To select the signal format, push the
FORMAT
button.
f.
Use the left (◄) or right (►) arrow button, or push the
FORMAT
button
repeatedly, to select the 1080 59.94i signal format.