Using the Live Capture Web Application
Live Capture Controls and Operation Status
144
Lightspeed Live Capture User Guide
Channel Previews Controls
Record All
—Select
Record All
to record the currently ganged channels.
Record All
operates in two different modes depending on whether
Time-Shift
has been enabled in the
workflow. (See the Capture action man page for details about Time-Shift.)
•
When Time-Shift is NOT enabled
in the workflow, all channels start recording
immediately with no attempt to synchronize the start timecode.
•
When Time-Shift has been enabled
in the workflow, the system attempts to syn-
chronize all of the selected channels to the exact same start timecode before start-
ing the recording. When recording starts, some portion of the frames in the Time-
Shift buffer are added to the start of the recorded file (going back in time to
included frames from the past). As a rule, add 10 seconds of Time-Shift for each
ganged channel. For example, in a Live Capture system consisting of three servers
capturing 12 channels (4 per server) each channel should be given 40 seconds of
Time-Shift (4 channels X 10 seconds per channel = 40 seconds).
•
Note
that all ganged channels must use the same timecode source in order to be