Teleorigin RB900SG User Manual Download Page 1

 

 

Summary of Contents for RB900SG

Page 1: ...1...

Page 2: ...s 11 Power supply connector 13 SIM card holder 14 Product sticker 15 Basic features and services 16 Using the modem 17 Setting up the modem 17 Mounting the modem 20 Status of the modem LEDs 22 RESET a...

Page 3: ...3 Power supply 36 RF specification 37 External antenna 38 Environmental characteristic 38 Accessories 39 Declaration of conformity 42 Safety Recommendations 43 List of acronyms 45 Online support 47...

Page 4: ...4 APPLICABILITY TABLE Modem Short description RB900SG E5 4G Cat 4 modem version RELATED DOCUMENTS 1 Teleorigin Manager User Manual 2 RB900SG E5 RED Declaration of Conformity...

Page 5: ...and wide power supply range it is easy to integrate it with energy meters The RB900SG terminal enabling high speed data transmission SMS and TCP IP communication The device can be controlled by standa...

Page 6: ...Description RB900SG E5 X X 2 X X LTE Cat 4 modem It is possible to use SIM CHIP solution Example P N of the modem with SIM CHIP RB900SG E5 X C 2 X X LTE Cat 4 modem with SIM CHIP Last parameter in P...

Page 7: ...7 Complete package contents Standard package contains RB900SG modem item A RJ45 cable item B Please check additional accessories in 11 Accessories A A B...

Page 8: ...ation Product pictures SMA antenna connector Extractable SIM card holder SIM card holder ejector Power supply RESET button USB POWER NET TYPE SIGNAL CONNECTION NET STATUS LED s RJ45 connector RS232 48...

Page 9: ...of GSM UMTS LTE is low or none an outdoor or indoor for instance in place where GSM UMTS LTE range is sufficient antenna should be used Note If there is no antenna connected to SMA connector the conn...

Page 10: ...e RB900SG terminal is equipped with a USB interface as shown below Type of connector is miniUSB It is used for device configuration NOTE To configure the modem with SIM card inside please plug also th...

Page 11: ...e jumper positions are presented in 7 1 Setting up the modem The connector also carries the power supply from the ITRON SL7000 or ACE6000 meter therefore it is not necessary to use an external power s...

Page 12: ...12 Pinout of the RJ45 DB9 adapter female for the RS232 interface RJ45 DB9 female RS232 1 VCC 2 3 4 TX 2 5 RX 3 6 GND 5 7 DTR 8...

Page 13: ...supply connection which can handle voltage from range 5 30 V DC 2 5 W max continuous power for modem with internal battery Pin I O Description I 5 V 30 V DC Ground Attention An attempt to power termin...

Page 14: ...accessible externally To insert a SIM card into the holder press the yellow button eject the little drawer place the SIM card inside and insert drawer into the modem you will hear click To operate the...

Page 15: ...tickers are on the modem and on the box of the product They includes the following informations and markings product serial number IMEI model signature CE marking 15 digit bar code manufacturer addres...

Page 16: ...1 B3 B7 B8 B20 B28A WCDMA B1 B8 GSM 900 1800MHz Work with Itron electricity meters SL7000 ACE6000 Physical Size 100 x 70 x 27 mm Weight 170 g Interfaces Connectors SMA for GSM LTE antenna SMA for GNSS...

Page 17: ...please connect the modem to Teleorigin Manager and choose 422 in Serial Serial type in Basic menu tab save the configuration and reboot the modem To change the interface to RS485 open the device housi...

Page 18: ...al document If you can t connect to the modem follow these steps check if the modem is connected to the computer via USB interface check if the COM port number is correct Disconnect the USB cable afte...

Page 19: ...nto the modem Connect the modem with the meter using RJ45 cable the modem will be powered directly from the meter and mount it in the meter housing For assembly description see Modem assembly Now the...

Page 20: ...20 Mounting the modem To mount the modem inside the meter housing please use one of the handles The available handles are shown in the photos below...

Page 21: ...21 The method of mounting the modem in the ITRON SL7000 housing is shown in the photo below...

Page 22: ...250ms on CSQ 16 250ms on 750ms off CSQ 6 off CSQ 6 or device not registerd to the network CONNECTION green on tcp server on and client connected to the server 500ms on 500ms off tcp server on no clie...

Page 23: ...n the command is sent via SMS and Teleorigin Manager Console tab 1 Device commands RB900SG Commands RB900SG GET FW VERSION CR LF Downloads the firmware version number of the microcontroller Response x...

Page 24: ...57 04 2021 LF CR LF RB900SG LOG PRINT CR LF Sends all entries from the event log Response 0d 00 00 01 L x x x CR LF 0d 00 00 15 L SIM ready CR LF 0d 00 00 31 L GSM registered CR LF 0d 00 00 32 L GPRS...

Page 25: ...vated CR LF 0d 00 00 33 L Sync to NTP success CR LF 0d 00 00 33 L Data port opened CR LF 0d 00 00 34 L Cfg port opened CR LF ETX RB900SG LOG FORMAT CR LF Removes all entries from the event log Respons...

Page 26: ...LLOWLIST STATUS CR LF Returns information whether allowlist is on or off Response xxxxxxx CR LF Response example DISABLE CR LF PHONE ALLOWLIST LIST CR LF Returns a list of numbers added to an allowlis...

Page 27: ...e As above PHONE ALLOWLIST REMOVE phone_number CR LF Removes the given phone_number from the allowlist Where phone_number phone numer in national or international format Response OK CR LF Response exa...

Page 28: ...xxxxxxxx xxxxxxxx xxxxxxxx CR LF Response examples internet CR LF or internet username password CR LF Where internet is apn username is username password is password CONFIG SET TCP PORTS data_port con...

Page 29: ...d Response xxxx CR LF Response example 1111 CR LF CONFIG SET ANTENNA type CR LF Sets the antenna to external or internal type Where type type of antenna options EXTERNAL INTERNAL Response OK CR LF Res...

Page 30: ...l be added also x xx xx format option under development Response example 1 1619515560 CR LF Where 1 is time 1619515560 is start_time there will be added also 1 10 30 format option under development CO...

Page 31: ...xx CR LF Response example Test comment CR LF CONFIG SET RTC SOURCE source CR LF Sets the internal clock sync source Where source clock source options GSM time from GSM network NTP ntp_addr ntp_port ti...

Page 32: ...only Response OK CR LF Response example As above CONFIG GET NETWORK SEARCH MODE CR LF Returns the network search mode Response xx CR LF Response example 2G CR LF CONFIG SAVE CR LF Saves configuration...

Page 33: ...in Manager User Manual NOTE It is recommended not to disconnect the modem s power supply during the update procedure Emergency update If the update was unsuccessful open the device housing short the t...

Page 34: ...dem serial interfaces USB power supply check that the power supply is correct see Power connector check that the COM port is correct check that the Teleorigin Manager program is working properly and t...

Page 35: ...35 Technical specifications Mechanical specifications Max dimensions 100 x 70 x 27 mm Weight 120 g Volume 170 cm3 Sketch of the housing...

Page 36: ...36 Electrical specification Power supply Nominal voltage range 5 30 V 10 Maximum continous average supply range 2 5 W Maximum continous average supply current 200 mA at 12V 100 mA at 24V...

Page 37: ...37 RF specification RB900SG E5...

Page 38: ...t it is used in When the modem is placed in a room or somewhere where the range of networks signal is too low an outdoor or a specific indoor antenna should be used Environmental characteristic Table...

Page 39: ...39 Accessories The pictures below show the available accessories for the RB900SG modem RJ45 RJ45 25cm cable Meter handle 1...

Page 40: ...40 Meter handle 2 Wall handle Screws for handles LTE antenna...

Page 41: ...ry Product code RJ45 RJ45 25cm cable RJ451125CMCA Handle 1 RB9HANDLEA1 Handle 2 RB9HANDLEA2 Wall handle RB9HANDLEA3 Screws for handles RB9SCREWS03 LTE antenna LTEANT0B04EX Internal antenna LTEANTP062I...

Page 42: ...The RB900SG product was assessed with the participation of a Notified Body in terms of meeting the essential requirements of Directive 2014 53 EU RED regarding radio equipment to demonstrate complian...

Page 43: ...y doubt please refer to the technical documentation and the regulations in force Every module has to be equipped with a proper antenna with the correct specifications The antenna has to be installed w...

Page 44: ...antenna with exact specifications The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body 20 c...

Page 45: ...erface DCD Data Carrier Detected DCE Data Communications Equipment DRX Data Receive DSR Data Set Ready DTA Data Terminal Adaptor DTE Data Terminal Equipment DTMF Dual Tone Multi Frequency DTR Data Ter...

Page 46: ...ncy Table PUK PIN Unblocking Code RACH Random Access Channel RLP Radio Link Protocol RMS Root Mean Square RTS Ready To Send RI Ring Indicator SAR Specific Absorption Rate e g of the body of a person i...

Page 47: ...latest version of this document technical suport latest version of Teleorigin Manager software and documentation This informations can be found also on our website at www teleorigin com For further i...

Page 48: ...48...

Reviews: