10
D-Sub 15-pin connector
The RB900-Pro terminal is equipped with a D-Sub DE15F 15-pin connector to control
the RS232 interface, RS232 AUX/Debug/MCU/Modem (option) or RS485 Modem/MCU
(option).
Table of DB9 pins:
Pin No.
Name
Dir
Description
1
DCD
OUT
Data Carrier Detect. Raised by DCE when modem
synchronized.
2
TXD
IN
Transmit Data (a.k.a TxD, Tx). Sending data from DTE.
3
Boot
Modem boot
4
NC
-
-
5
NC
-
-
6
RXD
OUT
Receive Data (a.k.a RxD, Rx). Arriving data from DCE.
7
DSR
OUT
Data Set Ready. Raised by DCE to indicate ready (optionally
RS485 A)
8
DTR
IN
Data Terminal Ready. Raised by DTE when powered on. In
auto-answer mode raised only when RI arrives from DCE.
9
GND
-
Ground
10
NC
-
-
11
CTS
OUT
Clear To Send. Raised by DCE in response to RTS from DTE.
12
RTS
IN
Request To Send. Raised by DTE when it wishes to send.
Expects CTS from DCE.
13
RI
OUT
Ring Indicator. Set when incoming ring detected - used for auto-
answer application.
14
Reset
IN
Modem reset
15
NC*
-
Not connected in standard version*
* - Analog Input 0, 0-10V as an option