Remote Control Touch
User Guide
Datum: 08.12.2015
Seite 29 von 61
RCTouch_UserGuide_V2.1.1.doc
The device status may display the following messages:
Message
Form
Meaning
Data recording
ERROR
red flashing
device in error mode
jeopardized
FWUPDATE
dark blue flashing
logger firmware is updated
stopped
MEMORY
dark blue flashing
lack of memory capacity
jeopardized
OK
dark blue
normal operation
normal
RING
dark blue flashing
logger in ring buffer mode
normal
WARNING
dark blue flashing
jeopardized operation
normal
Table 8.4: Device status messages
More information on the device status in provided in the user guides of the data loggers, section
10.5 Memory space and level.
The following types of devices exist:
Message
Type
RCTouch
Remote Control Touch
BP Mini
blue PiraT Mini
BP2 MB1.x
blue PiraT2
BP2 MB2.x
blue PiraT2 5E
Table 8.5: Device types
In MOST150 the following categories of messages exist:
Category
Meaning
Control
Control data; for the passing of control messages; transmits up to 384
data byte
MDP
MOST Data Packet; transmits up to 1524 data byte
MEP
MOST Ethernet Packet; for the passing of Ethernet messages; transmits
up to 1506 data byte
Streaming Chan-
nel/Channels
Synchronous data range; transmits up to 372 data byte
Channel
Busload/Size
Messages
*Number of streaming channels*
Streaming Channels
*Bus load in bytes* B
(remains
empty)
With only one streaming channel, the display under
“Channel” is restricted
to “Streaming Channel”.
Table 8.6: Message categories