Programmable Sweep Instruction Manual
CONFIGURATION
telemark.com
41 of 58
Rev 1.0.0
5.8.3 Figure 8
Differs from the Sin by a fixed sine pattern with 2:1 amplitude and frequency ratio. The
Figure 8 pattern amplitude can reach the outer limits of the pocket boundary.
Figure 5-17, Setup Pattern, Figure 8
Freq
–
Frequency 0.1Hz to 80Hz
Rotation
–
Rotation speed of the complete pattern, -20Hz to +20Hz, positive values for
CCW rotation.
Phase
–
Relative phase rotation of the complete pattern line (only visible when the
rotation is 0), -359 degrees to 359 degrees
Amp
–
Amplitude, 20-100% of configured maximum pocket
LDC Tail
–
Display of the history of the pattern, 10 to 1000
Profile
- -10.0 to 10.0