background image

2. 

2.1 

2.2 

Installation Tests

During testing, the NTBA must be in the

normal mode and the terminal resistors

must not be installed.

Testing the Connection Sockets

A patch cable is used to sequentially check each 

connection socket

(See below for the evaluation of the displayed 

results.)

ISDN Terminal Device Connecting Cord

Connect the cord to the 

UTC9

.

(See below for the evaluation of the displayed 

results.)

Expanded Test for SO Bus Installation

Where an ISDN installation contains more than 

one ISDN terminal device, leads 2a and 2b must 

not be reversed.

To eliminate the possibility that these two leads 

are reversed, lead 2a is interrupted at the first 

opportune location in the ISDN installation. This 

interruption of lead 2a must then be indicated on 

the 

UTC9

 at the connection socket. If the 

UTC9

 

indicates that lead 2b is interrupted, the leads 

have been reversed.

Once all reversals have been corrected, the 

interruption to lead 2a can be removed.

3. 

Example: 6 + 7 reversed

In the case of crossed wires, the correct

wiring can only be ensured if the shield is

also connected. Otherwise, interrupt any

lead at the transmitter and check that the 

associated indicator on the receiver fails to

go on.

Frequency/step

1 2 3 4 5 6 7 8 9

1
2
3
4
5
6
7
8
S

LE

D

ISDN Test (ISDN LED)

Only the receiver is required to test 

ISDN- S0 connections.

NTBA Connection Test

Test the ISDN connection at the NTBA in both 

the normal and emergency modes.

Normal mode: NTBA is connected to the 230V 

mains power supply.

Emergency mode: NTBA is 

not

 connected to the 

230V mains power supply. The connection is 

supplied by Telekom.

In the normal mode, all LEDs (ISDN) on the 

UTC9 are 

green

 while in the emergency mode 

they are 

red

.

The prerequisite for the test is the proper

NTBA function and connection.

CAUTION

For technical reasons LED 3+6 also on the 

LAN wiring tester go on in the normal mode 

and LED 4+5 in the emergency mode even if 

the wiring is correct!

1. 

Example: Short circuit between 3 + 4

Example: Interruption at 5

Frequency/step

1 2 3 4 5 6 7 8 9

1
2
3
4
5
6
7
8
S

LE

D

Frequency/step

1 2 3 4 5 6 7 8 9

1
2
3
4
5
6
7
8
S

LE

D

Reviews: