Technical data
Telecommunica-
tion
technical data
Supply voltage
Supply current
Call detection
24 – 64 V DC
20 – 50 mA
20 - 50 Hz
Inputs for bell
pushbuttons
Number
4
Call numbers
Number
per button 2 call numbers with
20 positions
Relay switching
outputs
Relay switching output
1
Relay switching output
2
potential-free, 24 V AC /
DC 1 A
potential-free, 24 V AC /
DC 1 A
General data
Power supply
Cable length
Power supply
Current consumption
Degree of protection
Operating temperature
Weight
9 - 24V, 0.5 A
max. 50 m
Standby 0.5 W
Call state max. 1 W
IP20
-20 °C to +60 °C
100 g
Dimensions
Cable length, micro
Device
300 mm
84 x 109.5 x 29 mm
3.5
Accessories
▪
Wall power supply unit article number 114737
(For power supply to the DoorLine TM4)
▪
Wall power supply SNG DL article number 105248
(For use as bell transformer, door opener current supply, etc. Cannot be
used for power supply to the DoorLine TM4!)
▪
Power unit for carrier rail assembly (DIN rail), article number 114651 (for
voltage supply to the DoorLine TM4).