background image

Assembly and connection

4

DoorLine Slim DECT

17 / 56

4.6.3

Terminal assignment

The rear side of the device has two screw-in/terminal plug-in connectors. They
can be unplugged for convenient connection of the lines.

Labelling is on the rear side of the housing.

View from the rear

View of terminals

1

Supply v12 V

7

SwitchBox data

2

Supply voltage GND

8

SwitchBox -

3

Relay contact 2
potential-free

9

Swi

4

Relay contact 2 
potential-free

10

not assigned

5

Relay contact 1 
potential-free

11

not assigned

6

Relay contact 1 
potential-free

Summary of Contents for DoorLine Slim DECT

Page 1: ...Operating and Assembly Instructions Door Intercom System DoorLine Slim DECT...

Page 2: ...e your feedback at any time if you find a mistake that we overlooked These Operating Instructions also use the term device to refer to the DoorLine Slim DECT The private branch exchange system is also...

Page 3: ...3 4 5 Installing device 13 4 5 1 Installing mounting plate on the wall 13 4 5 2 Installing device on mounting plate 14 4 6 Connecting device 15 4 6 1 Important notes 15 4 6 2 Wiring 16 4 6 3 Terminal...

Page 4: ...for call forwarding 35 5 14 2 Deleting call numbers for call forwarding 36 5 15 Configuring relay contacts 36 5 15 1 Configuration of relay contact 1 37 5 15 2 Configuration of relay contact 2 38 6 C...

Page 5: ...tents DoorLine Slim DECT 5 56 10 Maintenance care and disposal 54 10 1 Cleaning 54 10 2 Storage 54 10 3 Disassembly 54 10 4 Disposal 54 10 4 1 Disposing of packaging material 54 10 4 2 Disposing of ol...

Page 6: ...device repaired immedi ately The lines must not be installed or connected during storms Nor is it permit ted to insert or unplug the connection plug during storms The housing must not be opened under...

Page 7: ...ion 3 DoorLine Slim DECT 7 56 3 Product information and description Fig 1 Item Description 1 Bell pushbutton 1 capacitance 2 Bell pushbutton 2 capacitance 3 Brightness sensor 4 Microphone 5 Labelling...

Page 8: ...tion 8 56 DoorLine Slim DECT 3 1 Model variants DoorLine Slim DECT Surface Glass Colour Article number white 150720 black 150730 3 2 Nameplate The nameplate contains the serial number product coding a...

Page 9: ...ry if you connect a door opener if the relay contacts are accessible following disassembly of the DoorLine It is safer to configure a door opener via a SwitchBox accessories because this is located in...

Page 10: ...recom mend assembly on a standard in wall socket 3 5 Technical data Connection to the base Radio standard frequency range Range inside the building Range outdoors DECT GAP compatible 1881 1897 MHz up...

Page 11: ...for power supply to the DoorLine Slim DECT Power unit for carrier rail assembly DIN rail article number 114651 For power supply to the DoorLine Slim DECT SwitchBox SB 442 article number 151003 Surface...

Page 12: ...amaged and cause injury Protect the glass surfaces against damage 4 2 Scope of supply The scope of supply of the device includes the device Assembly and Operating Instructions mounting plate sealing f...

Page 13: ...mum distance from the microphone to the nearest corner wall sur face of at least 10 cm must be observed The ambient temperature must be between 20 C and 60 C In the area of the installation location n...

Page 14: ...reholes 3 onto the wall with screws and dowels 4 Press the sealing flange 4 into the recess on the mounting plate 1 4 5 2 Installing device on mounting plate Fig 3 1 Connect the terminals 1 see chapte...

Page 15: ...transformer e g 12 V alternating voltage must not be used as a power supply for the device This can result in destruction of the device Both integrated relay contacts connect potential free i e an add...

Page 16: ...es of lines If one of the connected lines is routed out of doors you will have to provide sufficient lightning protection Lines types that can be used Telecommunication indoor cable J Y ST Y 2 x 2 x 0...

Page 17: ...d for convenient connection of the lines Labelling is on the rear side of the housing View from the rear View of terminals 1 Supply voltage 12 V 7 SwitchBox data 2 Supply voltage GND 8 SwitchBox 3 Rel...

Page 18: ...mbly and connection 18 56 DoorLine Slim DECT 4 6 4 Wiring diagram Fig 4 Item Description A DoorLine rear side B Wall power supply C DECT compatible PBX system D SwitchBox E Relay contact 2 F Relay con...

Page 19: ...DoorLine Slim DECT 19 56 4 6 5 Connection example for a door opener and a door bell Item Description A DoorLine rear side B Wall power supply G Door bell to relay contact 1 H Door opener to relay con...

Page 20: ...m first change the DoorLine to registration mode The time required can vary accord ing to the PBX system 1 Apply the voltage supply The DoorLine starts up If the surrounding area is dark the DoorLine...

Page 21: ...e DoorLine A remedy in such a case can be provided by reconfiguring your PBX system It has to be set such that the DoorLine does not react to external calls 1 Call the DoorLine from a telephone that i...

Page 22: ...flashing Medium signal 1 fold flashing Weak signal Continuous flashing No connection to the PBX system or not registered No flashing Signal present but too weak for reliable operation Continuous flash...

Page 23: ...2 Remove the paper 3 Label the paper as desired 4 Place the paper in the drawer 5 Push the drawer to close it Insertion label blank Paper size 50x69 5 mm Fig 5 You can find our Label Assistant on our...

Page 24: ...on of relay contact 1 External gong for all bell pushbuttons Configuration of relay contact 2 Door opener SwitchBox None 5 2 Restoring factory settings 1 Enter the configuration mode see chapter Entry...

Page 25: ...tomatically and saves the changed configuration 5 5 Entry to configuration mode For configuration you have to call your DoorLine with a touch tone dialling telephone The way you can call the DoorLine...

Page 26: ...ted If you are in programming mode you can carry out all configuration options one after the other 5 6 Defining microphone sensitivity and volume The microphone sensitivity and volume of the loudspeak...

Page 27: ...one You will hear the neutral acknowledgement tone 4 Enter new 4 digit PIN Code You will hear the neutral acknowledgement tone 5 Repeat new PIN Code You will hear the positive acknowledgement tone If...

Page 28: ...fig uration mode 25 2 Actuate the hashtag button and star button on the tele phone 3 Enter configuration command for call number bell push button 1 11 at the telephone 4 Neutral acknowledgement tone 5...

Page 29: ...ton on the tele phone 3 Enter configuration command for call number bell push button 1 11 at the telephone 4 Neutral acknowledgement tone 5 If no input is made for 5 seconds you will hear the positive...

Page 30: ...button on the tele phone 3 Enter configuration command 04 at the telephone As confirmation you will hear a neutral acknowledgement tone 4 Enter digit 1 to enable the door opener function or digit 0 to...

Page 31: ...u will hear the positive acknowledgement tone With door opening with redial 8 If relay contact 1 was defined as door opener or if a contact of a SwitchBox was defined as door opener with redial 8 1 En...

Page 32: ...ps of 1 minute or 0 for without limitation 1 Enter the configuration mode see Entry to configuration mode 25 2 Actuate the hashtag button and star button on the tele phone 3 Enter configuration comman...

Page 33: ...will hear a neutral acknowledgement tone 4 Enter call duration with digits 01 99 in steps of one second The input must have two digits Finally you will hear the positive acknowledgement tone 5 13 Call...

Page 34: ...r the configuration mode see chapter Entry to con figuration mode 25 2 Actuate the hashtag button and star button on the tele phone 3 Enter configuration command 71 at the telephone You will hear the...

Page 35: ...The extension line on which the DoorLine is registered must have an authorisa tion for receiving external telephone calls In most telephone systems this function is referred to as direct outward dial...

Page 36: ...ernative number enter configuration com mand 52 at the telephone 4 Neutral acknowledgement tone 5 If no input is made for 5 seconds you will hear the positive acknowledgement tone and the call number...

Page 37: ...d in accordance with the follow ing table You will hear the positive acknowledgement tone as con firmation Switching command Bell push button Bell push button Redial Comments 1 2 8 0 Relay contact 1 c...

Page 38: ...on and star button on the tele phone 3 Enter configuration command 62 at the telephone Neutral acknowledgement tone 4 Enter switching command in accordance with the follow ing table You will hear the...

Page 39: ...witchBox SB 442 or Enter digit 0 if no SwitchBox is to be used Finally you will hear the positive acknowledgement tone 6 2 Defining PIN Code for SwitchBox For security reasons communication between th...

Page 40: ...wledgement tone This can take a few seconds or If an error occurred you will hear the negative acknow ledgement tone 8 short beeps After the third unsuccess ful attempt the connection is disconnected...

Page 41: ...configuration command 63 at the telephone Neutral acknowledgement tone 4 Enter switching command in accordance with the follow ing table You will hear the positive acknowledgement tone as con firmati...

Page 42: ...configuration command 64 at the telephone Neutral acknowledgement tone 4 Enter switching command in accordance with the follow ing table You will hear the positive acknowledgement tone as con firmatio...

Page 43: ...configuration command 65 at the telephone Neutral acknowledgement tone 4 Enter switching command in accordance with the follow ing table You will hear the positive acknowledgement tone as con firmatio...

Page 44: ...no SwitchBox 1 use SwitchBox 02 PIN old PIN new PIN new Change PIN Code for Switch Box 04 Door opener func tion Door opener function 0 disabled 1 enabled Factory setting disabled 05 Door opener time S...

Page 45: ...ration of relay con tact 1 See Configuring relay contacts 36 62 Command 0 3 Configuration of relay con tact 2 See Configuring relay contacts 36 63 Command 0 4 Configuration of SwitchBox re lay contact...

Page 46: ...ECT Programming command Own settings Description 99 Reset to factory setting 2 Reduce microphone sensitiv ity 3 Increase microphone sensitiv ity 5 Reduce loudspeaker volume 6 Increase loudspeaker volu...

Page 47: ...of the called connection rings With call mode Mute connection setup and Connection setup with tone output 1 Pick up telephone Voice communication is established directly 2 Hang up the receiver to end...

Page 48: ...is established directly 2 Simply hang up the receiver to end the voice communic ation or enter digits 0 disconnects the connection immediately or the maximum call duration is reached The connection i...

Page 49: ...can be set from 1 9 seconds see chapter Defining door opener time 30 8 3 Calling the DoorLine The DoorLine can also be called directly Setting up connection 1 Pick up telephone 2 Enter the call number...

Page 50: ...telephone or another telephone Prerequisites The call numbers for call forwarding must be defined in advance see chapter Defining absence numbers 35 Activating call forwarding 1 Pick up telephone 2 C...

Page 51: ...phone 2 Call the DoorLine You will hear the positive acknowledgement tone 3 Press the hashtag button 4 Enter digit 1 2 for the relevant bell pushbutton 5 Enter digit 0 for deactivation You will hear t...

Page 52: ...rwarding to absence numbers button 1 Deactivates call forwarding to absence numbers button 2 Activates call forwarding to absence numbers button 2 or Activates the door opener Function is only availab...

Page 53: ...utton lamp DoorLine is not re gistered in the tele phone system Register DoorLine in accordance with chapter DoorLine registration 20 in the telephone system Rapid continuous flash ing of the button l...

Page 54: ...de energise all components used Proceed in reverse sequence to assembly see Installing device on mounting plate 14 10 4 Disposal 10 4 1 Disposing of packaging material All packaging materials are envi...

Page 55: ...DoorLine Slim DECT 55 56...

Page 56: ...of the Hotline incurs the normal connection costs Teleg rtner Elektronik Hotline Tel Monday Thursday Friday service telegaertner elektronik de 49 7951 488 9200 7 00 16 30 hours 7 00 13 00 hours Issued...

Reviews: