Expert Mode
Purpose
Turns on or off the expert mode.
Format
expertoff, experton
Recommended Setting. Use as needed.
Description
When the Expert Off command is used, it limits the amount of commands displayed on
the help menu. When the expert mode is turned off, all commands are still available (to
ensure software compatibility) but do not display. The Expert On command shows all of
the available commands in the help menu.
Examples
See below.
expertoff
Expert Mode is Off
>
experton
Expert Mode is On
>
OL - Features
Purpose
Lists special firmware upgrades that are installed.
Format
OL
Recommended Setting. Use as needed.
Description
Lists special features that are installed. See
for information on how to
install additional capability in your H-ADCP.
Examples
See below.
>ol FEATURES
---------------------------------------------------------------------
Feature Installed
---------------------------------------------------------------------
Bottom Track Yes
Water Profile Yes
High Resolution Water Modes No
Lowered ADCP No
Waves Gauge Acquisition No
See your technical manual or contact TRDI for information on how to