48
Operation
SeaBat Sonar UI - User Manual
Refer to Appendix ‘Raw Data Recording’ on page 93 for a full description
of how to setup RDR properly for different schemes.
4.8.1.2 Record Selection
Figure 4-53
Record selection
Next to the standard data records additional data records can be
recorded.
Standard data records are always included in the recording:
7000
– Ping settings
7004
– Beam geometry
7006
– Bathymetry (legacy)
7011
– Compressed image data
7017
– Bathymetry (for UI display)
7027
– Bathymetry (RAW)
7503
– Sonar settings
Operator selectable records are: (Select the associated check boxes.)
Snippets
:
7028
– Snippets data
Side scan
:
7007
– Backscatter data
Sensor data
(motion, position, heading, etc.):
1003
– Position
1012
– Attitude (Roll, Pitch and Heave)
1013
– Heading
7610
– Sound Velocity
Watercolumn
(includes sensor data):
7018
– Full Magnitude & Phase data
Compressed water column:
7042
– Compressed water column data
Troubleshooting
(includes water column data):
7021
– BITE data
Other
:
All other available records.
When the checkbox is ticked the record numbers will be
displayed at the bottom of the pane in the info box.