92
Appendix Dual head (Master
– Slave)
SeaBat Sonar UI - User Manual
by the master except the
bracket and trigger out
parameters.
The slave’s roll stab
parameters are set by the
master. However the slave
processor must be interfaced
with the motion sensor.
IO pane
All functions
X
The Master IO data is
echoed from the master 7K
Center to the slave 7K
Center. The IO page could
therefore not be modified
from the slave and also
notice the IO could not be
monitored by the slave IO
module.
6.4 BITE
The BITE LED indicates the (Alarm) status both for the Master and Slave
system. A red BITE indicates an error in the Slave or in the Master. To
access and check the service menu for the Slave it is necessary to open
the Slave by the slave sonar address as discussed in the ‘Setup’ section
above. When in the Slave, access the service menu for fault finding the
Slave system.