Be sure that any AC adaptors or extension cords provide all three connections (power, return 
and ground), and are of suitable rating for the charger product. 

DC Output Connection 

 

DC connections must be made before starting the charge cycle. 

 

Never use a cable that is worn, frayed, nicked or damaged or is in any other condition than will 
make a reliable connection to the battery. 

 

An intermittent cable connection will interfere with the proper operation of the charger. 

 

Do not disconnect the charger from the battery while the charge cycle is in operation. 

 

Be careful not to short the terminals of a battery together when connecting or disconnecting 
the DC connection. 

 

Make sure that the cable’s terminals are free of any corrosion.

 

Charger 

 

Never operate a charger that has been damaged in any way including impact, shock, or 
excessive exposure to moisture, plague, pestilence or locusts. 

 

Do not disassemble the charger.  No user serviceable parts inside.  Return the product to 
Teledyne Battery Products for service: call or email for return instructions. 

Personal Precautions 

 

Have plenty of fresh water and soap nearby in case battery electrolyte contacts skin, clothing 
or eyes.  Wear complete eye and skin protection when connecting, disconnecting, handling and 
charging batteries.  In the event of an accident, immediately flood the affected area with water 
and get medical attention.  

 

Someone should be within the range of your voice, aware of your activity, and be able to come 
to your aid when you are working with or near a battery. 

 

Never smoke, or allow a spark or flame, in the vicinity of a battery or engine. 

 

Remove jewelry 

 

Wear eye protection 
 

 

 

Summary of Contents for TDMC+

Page 1: ...rights reserved TDMC Teledyne Dual Mode 12 and 24 VDC Lead Acid Battery Charger Redlands CA 92374 1 800 456 0070 1 909 793 3131 support teledynebattery com Product Name TDMC Part Number TDMC 01 Docume...

Page 2: ...e 3 Product Description 4 Precautions and Warnings 5 Batteries 5 Location 5 Grounding and AC Power Cord 5 DC Output Connection 6 Charger 6 Personal Precautions 6 Charger Operation 7 Organization of th...

Page 3: ...oltage mode User selects charger voltage for 12V or 24V operation as appropriate for the battery to be charged by pressing the button in Screen Section A Caution If a 12V battery is charged with a 24V...

Page 4: ...Teledyne Battery Products TDMC is a battery charger for 12V and 24V lead acid batteries It offers two microprocessor controlled precision charging method a three stage charging method for normally dis...

Page 5: ...smooth even uncluttered surface Allow adequate airflow around the unit during charging to prevent overheating Maintain minimum 3 7cm distance to wall Do not use the charger on a soft carpeted upholste...

Page 6: ...C connection Make sure that the cable s terminals are free of any corrosion Charger Never operate a charger that has been damaged in any way including impact shock or excessive exposure to moisture pl...

Page 7: ...g cable to the Positive terminal on the battery Connect the Negative Black charging cable to the Negative terminal on the battery Reversing these connections results in the charger displaying a Revers...

Page 8: ...lete in the allotted time See charging Method details for allotted times Note in most Error conditions Selection Items A B C and D will vanish and the charger will not allow further operation until po...

Page 9: ...ging Charger is idle Red Stopped on Error Red Green Charging Green Charge Complete Connection Red Battery is reverse polarity Red Green Battery not detected Green Battery is connected correctly Charge...

Page 10: ...For Normally Discharged Lead Acid Battery Charge Method select End at 5A in Screen Section E With this selection the charger will follow the three stage charge mode recommended for use with all normal...

Page 11: ...dition The Deeply Discharged or Sulphated Lead Acid Battery Charge Method ending condition is based on time The time should be based upon the battery capacity in amp hours and the desired charging cur...

Page 12: ...the button in Screen Section F to start the charge cycle Details of the Two Stage Charge Mode 1 Stage 1 Constant Current Bulk Charge With the battery in a discharged state charging initiates in consta...

Page 13: ...of Stage 1 2 10 80 hours selectable Max Absorption Voltage 15 0V 100mV 30 0V 100mV Unit Specifications Electrical Input Voltage 85 VAC 270 VAC 50 60 Hz Max Power 250 Watts Configuration Line neutral c...

Page 14: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 15: ...battery 5 Verify DMM matches voltage on screen 5V 6 Press Pause 7 Verify DMM matches voltage on screen 2V 8 Set DMM to current mode connect DMM in series with battery 10A mode 9 Resume charge press Go...