Charging Specifications 

General Parameters 

12V Specification 

24V Specification 

Maximum Charging Current 

6A +/- .5A 

Standby battery Drain  

<100 uA with AC disconnected 

Voltage Regulation  

+/- .5% 

Output noise and ripple 

<150mV, 100MHz BW 

Efficiency 

Minimum 85% under worst line/load conditions 

3 Stage Parameters 

12V Specification

 

24V Specification

 

Max Absorption Voltage 

14.4V +/- 100mV 

28.8V +/- 100mV 

Absorption to Float Current 

500mA +/1 100mA 

500mA +/1 100mA 

Float Voltage 

13.15V +/- 100mV 

26.30V +/- 100mV 

Overvoltage Protection 

15.2V +/- 200mV 

30.4 +/- 200mV 

2 Stage Parameters 

12V Specification

 

24V Specification

 

Duration of Stage 1 + 2 

10 

 80 hours, selectable 

Max Absorption Voltage 

15.0V +/- 100mV 

30.0V +/- 100mV 

Unit Specifications 

Electrical Input 

Voltage 

85 VAC 

 270 VAC, 50/60 Hz 

 

Max Power 

250 Watts  

 

Configuration 

Line, neutral, chassis ground 

 

Connector 

IEC 60320  C14 power inlet (C13 cord plug) 

 

Supplied Cable 

18AWG grounded cord with NEMA 5-15 
grounded Type B wall connector 

Electrical Output 

  Voltage 

32 VDC maximum 

 

Current 

6A maximum 

 

Configuration 

Positive, Negative 

 

Connector 

Two pin circular 

 

Supplied Cable 

14 AWG battery cord with crocodile style 
battery clips 

Environment 

Orientation  

May be used horizontally or vertically 

 

Location 

For indoor use only. 

 

Operation 

-22F to 140F (-30C to 60C) 

 

Storage 

-40F to 176F (-40C to 90C) 

Certification 

UL (U.S) 

Under Evaluation 

 

CUL (Canada) 

Under Evaluation 

 

CE 

Under Evaluation 

 

FCC 

Compliant to Part 15 of FCC Rules 

Mechanical Dimensions 

(unit only)

 

Height 

11.5” (290mm) 

 

Depth 

5” (130mm) 

 

 

Width 

6” (150mm) 

 

 

Weight 

6 lbs (2.7 Kg) 

 

 

 

Summary of Contents for TDMC+

Page 1: ...rights reserved TDMC Teledyne Dual Mode 12 and 24 VDC Lead Acid Battery Charger Redlands CA 92374 1 800 456 0070 1 909 793 3131 support teledynebattery com Product Name TDMC Part Number TDMC 01 Docume...

Page 2: ...e 3 Product Description 4 Precautions and Warnings 5 Batteries 5 Location 5 Grounding and AC Power Cord 5 DC Output Connection 6 Charger 6 Personal Precautions 6 Charger Operation 7 Organization of th...

Page 3: ...oltage mode User selects charger voltage for 12V or 24V operation as appropriate for the battery to be charged by pressing the button in Screen Section A Caution If a 12V battery is charged with a 24V...

Page 4: ...Teledyne Battery Products TDMC is a battery charger for 12V and 24V lead acid batteries It offers two microprocessor controlled precision charging method a three stage charging method for normally dis...

Page 5: ...smooth even uncluttered surface Allow adequate airflow around the unit during charging to prevent overheating Maintain minimum 3 7cm distance to wall Do not use the charger on a soft carpeted upholste...

Page 6: ...C connection Make sure that the cable s terminals are free of any corrosion Charger Never operate a charger that has been damaged in any way including impact shock or excessive exposure to moisture pl...

Page 7: ...g cable to the Positive terminal on the battery Connect the Negative Black charging cable to the Negative terminal on the battery Reversing these connections results in the charger displaying a Revers...

Page 8: ...lete in the allotted time See charging Method details for allotted times Note in most Error conditions Selection Items A B C and D will vanish and the charger will not allow further operation until po...

Page 9: ...ging Charger is idle Red Stopped on Error Red Green Charging Green Charge Complete Connection Red Battery is reverse polarity Red Green Battery not detected Green Battery is connected correctly Charge...

Page 10: ...For Normally Discharged Lead Acid Battery Charge Method select End at 5A in Screen Section E With this selection the charger will follow the three stage charge mode recommended for use with all normal...

Page 11: ...dition The Deeply Discharged or Sulphated Lead Acid Battery Charge Method ending condition is based on time The time should be based upon the battery capacity in amp hours and the desired charging cur...

Page 12: ...the button in Screen Section F to start the charge cycle Details of the Two Stage Charge Mode 1 Stage 1 Constant Current Bulk Charge With the battery in a discharged state charging initiates in consta...

Page 13: ...of Stage 1 2 10 80 hours selectable Max Absorption Voltage 15 0V 100mV 30 0V 100mV Unit Specifications Electrical Input Voltage 85 VAC 270 VAC 50 60 Hz Max Power 250 Watts Configuration Line neutral c...

Page 14: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 15: ...battery 5 Verify DMM matches voltage on screen 5V 6 Press Pause 7 Verify DMM matches voltage on screen 2V 8 Set DMM to current mode connect DMM in series with battery 10A mode 9 Resume charge press Go...

Reviews: