Deeply Discharged or Sulphated Lead-Acid Battery Two Stage Charge Method 

For any deeply discharged lead-acid battery, configure the charger for the two-stage charge mode as 
follows: 

 

Connect (or Disconnect) a battery only when the charger is either unplugged from AC (off) or 

when the display indicates “

-not charging- 

 

Charger Voltage mode: 

Select

 charger voltage for 12V or 24V operation as appropriate for the 

battery to be charged by pressing the button in Screen Section C. 

Caution: 

If a 12V battery is charged with a 24V charge curve, the battery may be overcharged 

causing potentially serious damage.

 

 

Charger Current mode: 

Select 

for 6A to 1A as appropriate for the battery to be charged by 

pressing the button in Screen Section D. 

Caution

: On deeply discharged batteries, Teledyne Battery Products recommends a 1A charge 

curve and recommends not using a charge current (Amps) that is greater than 1/10 of the battery 
capacity in Amp hours. Always follow battery Component Maintenance Manual (CMM) guidance, 
consult the battery documentation, service bulletin or battery manufacturer for guidance or use 
the lowest 1A setting.

 

 

Charge Cycle End Condition: The Deeply Discharged or Sulphated Lead-Acid Battery Charge 
Method ending condition is based on time.  The time should be based upon the battery 
capacity in amp hours, and the desired charging current.  

select

 

an ending condition in hours

 in 

Screen Section E. 

 

Observe the Battery Capacity in Amp Hours (Ah) as recommended by the battery CMM 
section on Deep Discharge Recovery.  Round this number to the nearest 5 Amp-hours.   

 

Observe the selected charge current (1A).   

 

Calculate the charge time using the equation or the table provided. 

 

Calculation method:   

𝐵𝑎𝑡𝑡𝑒𝑟𝑦 𝐶𝑎𝑝𝑎𝑐𝑖𝑡𝑦 

(

𝐴ℎ

)

𝐶ℎ𝑎𝑟𝑔𝑒 𝐶𝑢𝑟𝑟𝑒𝑛𝑡 

(

𝐴

)

= 𝐶ℎ𝑎𝑟𝑔𝑒 𝑇𝑖𝑚𝑒 (ℎ𝑜𝑢𝑟𝑠)

 

Round the result down to the nearest 5 hours.  If the result 
returns less than 10 hours, the selected charge current is too 
high, select a lower charge current. 

 

Table Method 

 

Select the row (1) that corresponds to the Battery 
Capacity (Ah). 

 

Select the column (2) that corresponds to the desired 
charge Current (A). 

 

Identify the Charge Time at the intersection of the 
chosen row and column. 

 

Example 1: The Teledyne 7638-44 battery is a 24V, 44 Ah 
battery, 1A charge: 

 

The battery capacity is 44Ah, round to 45. 

 

Divide 45/1 = 45 

 

45 is already evenly divided by 5 

 

This column, row and result are marked in the table 

 

Battery Charge Timetable 

1

2

3

4

5

6

80

80 40 25 20 15 10

75

75 35 25 15 15 10

70

70 35 20 15 10 10

65

65 30 20 15 10 10

60

60 30 20 15 10 10

55

55 25 15 10 10

50

50 25 15 10 10

45

45 20 15 10

40

40 20 10 10

35

35 15 10

30

30 15 10

25

25 10

20

20 10

15

15

10

10

Charge Current (A)

B

at

te

ry

 C

ap

ac

it

(A

h

)

C

h

ar

ge

 T

im

e

 (

h

o

u

rs)

2

1

3

Summary of Contents for TDMC+

Page 1: ...rights reserved TDMC Teledyne Dual Mode 12 and 24 VDC Lead Acid Battery Charger Redlands CA 92374 1 800 456 0070 1 909 793 3131 support teledynebattery com Product Name TDMC Part Number TDMC 01 Docume...

Page 2: ...e 3 Product Description 4 Precautions and Warnings 5 Batteries 5 Location 5 Grounding and AC Power Cord 5 DC Output Connection 6 Charger 6 Personal Precautions 6 Charger Operation 7 Organization of th...

Page 3: ...oltage mode User selects charger voltage for 12V or 24V operation as appropriate for the battery to be charged by pressing the button in Screen Section A Caution If a 12V battery is charged with a 24V...

Page 4: ...Teledyne Battery Products TDMC is a battery charger for 12V and 24V lead acid batteries It offers two microprocessor controlled precision charging method a three stage charging method for normally dis...

Page 5: ...smooth even uncluttered surface Allow adequate airflow around the unit during charging to prevent overheating Maintain minimum 3 7cm distance to wall Do not use the charger on a soft carpeted upholste...

Page 6: ...C connection Make sure that the cable s terminals are free of any corrosion Charger Never operate a charger that has been damaged in any way including impact shock or excessive exposure to moisture pl...

Page 7: ...g cable to the Positive terminal on the battery Connect the Negative Black charging cable to the Negative terminal on the battery Reversing these connections results in the charger displaying a Revers...

Page 8: ...lete in the allotted time See charging Method details for allotted times Note in most Error conditions Selection Items A B C and D will vanish and the charger will not allow further operation until po...

Page 9: ...ging Charger is idle Red Stopped on Error Red Green Charging Green Charge Complete Connection Red Battery is reverse polarity Red Green Battery not detected Green Battery is connected correctly Charge...

Page 10: ...For Normally Discharged Lead Acid Battery Charge Method select End at 5A in Screen Section E With this selection the charger will follow the three stage charge mode recommended for use with all normal...

Page 11: ...dition The Deeply Discharged or Sulphated Lead Acid Battery Charge Method ending condition is based on time The time should be based upon the battery capacity in amp hours and the desired charging cur...

Page 12: ...the button in Screen Section F to start the charge cycle Details of the Two Stage Charge Mode 1 Stage 1 Constant Current Bulk Charge With the battery in a discharged state charging initiates in consta...

Page 13: ...of Stage 1 2 10 80 hours selectable Max Absorption Voltage 15 0V 100mV 30 0V 100mV Unit Specifications Electrical Input Voltage 85 VAC 270 VAC 50 60 Hz Max Power 250 Watts Configuration Line neutral c...

Page 14: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 15: ...battery 5 Verify DMM matches voltage on screen 5V 6 Press Pause 7 Verify DMM matches voltage on screen 2V 8 Set DMM to current mode connect DMM in series with battery 10A mode 9 Resume charge press Go...

Reviews: