The Mode field of the front panel display indicates to the user which operating
mode the unit is currently running.
Besides
SAMPLE
and
SETUP
, other modes the analyzer can be operated in are:
Table 4-1:
Analyzer Operating Modes
MODE MEANING
DIAG
One of the analyzer’s diagnostic modes is being utilized (See Section 4.13).
M-P CAL
This is the basic, multi-point calibration mode of the instrument and is activated by pressing
the
CAL
button.
SAMPLE
Sampling normally, flashing indicates adaptive filter is on.
SAMPLE A
Indicates that unit is in
SAMPLE
Mode and
AUTOCAL
feature is activated.
SETUP
SETUP
mode is being used to configure the analyzer (CO
2
sampling will continue during this
process).
SPAN CAL A
Unit is performing span cal procedure initiated automatically by the analyzer’s
AUTOCAL
feature.
SPAN CAL M
Unit is performing span cal procedure initiated manually by the user.
SPAN CAL R
Unit is performing span cal procedure initiated remotely via the RS-232, RS-4485 or digital i/o
control inputs.
ZERO CAL A
Unit is performing zero cal procedure initiated automatically by the analyzer’s
AUTOCAL
feature.
ZERO CAL M
Unit is performing zero cal procedure initiated manually by the user.
ZERO CAL R
Unit is performing zero cal procedure initiated remotely via the RS-232, RS-4485 or digital I/O
control inputs.
Finally, the various
CAL
modes allow calibration of the analyzer. Because of its
importance, this mode is described separately in Section 5.
4.2. SAMPLE MODE
This is the analyzer’s standard operating mode. In this mode the instrument is
analyzing the gas in the sample chamber, calculating CO
2
concentration and
reporting this information to the user via the front panel display, the analog
outputs and, if set up properly, the RS-232/485/Ethernet ports.
NOTE
A value of “XXXX” displayed in the CO2 Concentration field means that the M/R ratio is invalid
because CO2 REF is either too high (> 4950 mVDC) or too low (< 1250 VDC).
07272B DCN6552
Summary of Contents for T360
Page 2: ......
Page 188: ...This page intentionally left blank 07272B DCN6552 ...
Page 264: ...07272B DCN6552 ...
Page 320: ...This page intentionally left blank B 2 07272B DCN6552 ...
Page 324: ...This page intentionally left blank B 6 07272B DCN6552 ...
Page 327: ...APPENDIX D Wire List and Electronic Schematics D 1 07272B DCN6552 ...
Page 328: ...This page intentionally left blank D 2 07272B DCN6552 ...
Page 332: ...This page intentionally left blank 07272B DCN6552 D 6 ...
Page 333: ...07272B DCN6552 D 7 ...
Page 338: ...07272B DCN6552 D 12 ...