In Easy Mode, on the Capture tab, select to capture
Everything
or
Pattern
. For Pattern,
select a Pattern. You can exclude patterns and frames. You can use different patterns for
pre
‐
trigger and post
‐
trigger.
In Easy Mode, on the Trigger tab, select the trigger type. For Pattern, select the pattern.
In Easy Mode, on the Initiator Setting or Host Setting tab, select the port and speed.
Select to run the Pattern Generator or Initiator Emulator or Host Emulator.
In Easy Mode, on the Settings tab, select trigger position and memory use. Also change
the Analyzer settings if necessary. Specify addresses, stops, times, and sizes, if necessary.
Use Advanced Mode only after you become familiar with the hardware and software and
have special needs.
1.19 Performance
Analyzer
To do a Performance Analysis, select
File
>
New
>
SAS
Performance
Analyzer
for SAS
or
File
>
New
>
SATA
Performance
Analyzer
for SATA
.
Choose settings in the Performance
Analysis dialog. Click Run Hardware (see
“Performance Analysis” on page 178
1.20 Target Emulator or Device Emulator
To use the software as a target or device emulator, first select
File
>
New
>
SAS
Target
Emulator
or
SATA
Device
Emulator
for a new project or
File
>
Open
an existing Emulator
file:
.std
Target Emulator file or
.sde
Device Emulator file (see
). You can also use
Project Setup
>
Last
Target
Emulator
or
Last
Device
Emulator.
In the Pages tab, change settings for the supported pages if necessary.
In the Error Injection tab, select General periodic errors, Identify frames,
Connection Management open and close connection errors, SAS Commands and events
errors, ATA Commands errors, or SATA Signature content.
Use the User
‐
defined Commands tab only after you have become familiar with
operations.
In the Settings tab, select addresses, sizes, times, and ports, if necessary.
You can capture traffic when using an Analyzer project (but not a Target Emulator
project). With a Protocol Analyzer open, open a
Target
Emulator.
After checking the
settings, click the
Activate/Deactivate
(Active) device button. or select
Project Setup
>
Active
Device.
If you change Target Emulator settings,
Deactivate
and then
Activate
Device
.
1.21 Teledyne LeCroy SAS/SATA Protocol Suite Menu Options and
Toolbars
This section lists all the SAS/SATA Protocol Suite application menu options and the
toolbars.
Summary of Contents for Sierra M6-2
Page 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Page 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Page 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Page 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...