
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
111
Projects
Teledyne LeCroy
this, the code violation is not triggered during the speed negotiation phase, but is
triggered if the violation happens after the speed negotiation phase.
External Trig Out Setting
The Analyzer can send a Low or High external signal when a trigger occurs. Under
Setup
select
External
Trig
Setting
to choose External Trig Out Setting: High Active, Low Active, or
Toggle from High to Low or Low to High once (3.3 V output). Enter the External TrigOut
pulse width.
The pulse width is programmable in the software. The Voltage level is 0 to +3.3 Volt. The
trigger out is derived by NL17SZ126 buffer. The delay for OOB traffic external trigger out is
330 ns. The delays for non OOB external trigger out are:
6G ~ 370 ns
3G ~ 540 ns
1.5G ~ 850 ns
The delays for external trigger out with OOB traffic is 330 ns.
Summary of Contents for Sierra M6-2
Page 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Page 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Page 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Page 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...