SeaBat T-Series Subsea Operator's Manual
Page 107
January 31, 2019
Version 7
To avoid damage to the system components, the SSP connections
must
be made according to
the labelling on the bottle:
SINGLE HEAD
TX1:
Dual or single frequency, deep operation:
TC2160, 400kHz projector
or: Single frequency, deep operation:
TC2163, 200kHz projector
or: Dual frequency, shallow operation:
TC2181, 200-400kHz projector
TX2:
Dual frequency, deep operation:
TC2163, 200kHz projector
RX1:
EM7219-1, dual-frequency receiver
or: EM7218-1, dual-frequency receiver
INTEGRATED DUAL HEAD
29
TX1 and TX2,
2 identical projectors:
TC2160, 400kHz projector
or: TC2163, 200kHz projector
or: TC2181, 200-400kHz projector
RX1 and RX2
30
,
2 identical receivers:
EM7219-1, dual-frequency receiver
or: EM7218-1, dual-frequency receiver
Figure 65: SSP Pressure Bottle Connections
CAUTION
To disconnect wet-end cables from the SSP, first unscrew the locking sleeves before pulling
the cables out.
CAUTION
Do not bend the cables beyond the recommended limits when positioning the cables. These
cables are very stiff, and a smaller bend radius will damage the cable.
CAUTION
Do
not
open the Fill valve (for Teledyne RESON use only). Noncompliance will affect
warranty situation (see
Appendix G Warranty Information
).
29
Dual head configurations with two SSPs are also available.
30
Not labelled on the bottle itself.
Summary of Contents for SeaBat T Series