![Teledyne Linea GigE 2K User Manual Download Page 38](http://html1.mh-extra.com/html/teledyne/linea-gige-2k/linea-gige-2k_user-manual_1080498038.webp)
36
•
Operational Reference
Linea GigE Series Camera
I/O Control Feature Descriptions
The following table describes these features along with their view attribute and minimum camera
firmware version required. Additionally the Device Version column will indicate which parameter is
a member of the DALSA Features Naming Convention (indicated by DFNC), versus the GenICam
Standard Features Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Linea GigE capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by green text for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
Trigger Selector
TriggerSelector
Selects which type of trigger to configure with the
various Trigger features.
1.00
Beginner
Single Line Trigger (Start)
LineStart Selects a trigger starting the capture of a single
line.
Single Frame Trigger(Start)
FrameStart Selects a trigger starting the capture of a single
frame. Frame size is determined by image format
feature “Height”.
MultiFrame Trigger(Start)
FrameBurstStart Selects a trigger to capture multiple frames. The
number of frames is specified by the
triggerFrameCount feature.
Frame Active
FrameActive Selects a trigger controlling the duration of one
frame.
Frame Burst Active
FrameBurstActive Selects a trigger controlling the frame(s) duration.
One trigger can start many frames if the duration
exceeds the size of one frame.
TriggerMode
Controls the enable state of the selected trigger.
1.00
Beginner
Off
Off The selected trigger is turned off.
On
On The selected trigger is turned active.
Trigger Frames Count
triggerFrameCount
Sets the number of frames to acquire when a valid
trigger is received. This feature is available when
the Trigger Selector is set to MultiFrames Trigger.
1.00
DFNC
Beginner
Trigger Line Count
triggerLineCount
Sets the number of lines to acquire when a valid
line trigger pulse is received.
1.00
DFNC
Beginner
Software Trigger
TriggerSoftware
Generate a software command internal trigger
immediately no matter what the TriggerSource
feature is set to.
1.00
Beginner
Trigger Source
TriggerSource
Specifies the internal signal or physical input line
to use as the trigger source. The selected trigger
must have its TriggerMode set to ON.
Note, source availability may depend on the
TriggerSelector setting.
See Input Signals Electrical Specifications.
1.00
Beginner
Line 1
Line1 Select Line 1 (and associated I/O control block) to
use as the external trigger source. See
LineSelector feature for a complete list.
Line 2
Line2 External Trigger on Line 2.
Line 3
Line3 External Trigger on Line 3.
Line 4
Line4 External Trigger on Line 4.
Rotary Encoder
rotaryEncoder1 Select Rotary Encoder to use as the external line
trigger source.
Timer1End Event
Timer1End Select the Timer1End Event as the internal trigger
source.
Timer2End Event
Timer2End Select the Timer2End Event as the internal trigger
source.
Summary of Contents for Linea GigE 2K
Page 101: ...Linea GigE Series Camera Network Overview Tools 99...
Page 106: ...104 Technical Specifications Linea GigE Series Camera...
Page 112: ...110 Technical Specifications Linea GigE Series Camera EC FCC Declarations of Conformity...
Page 113: ...Linea GigE Series Camera Technical Specifications 111...