Nano Series GigE Vision Camera
Troubleshooting
•
267
Random Invalid Trigger Events
•
Do not change the exposure time while grabbing, else an Invalid Trigger Event may be
generated. This applies to any exposure mode or trigger source. The Invalid Trigger Event is
not catastrophic and only indicates the loss of a video frame. Stopping acquisitions first will
avoid this error.
•
Version 1.00 firmware may not correctly generate Invalid Trigger Events when triggers are
received early (i.e. within the trigger exclusion period). All trigger management issues will be
resolved with firmware 1.01.
Minimum Sapera Version Required
Save User Configuration Failed: An unusual error that occurred with no other Nano control
problem. The solution is to verify the minimum Sapera version used with the Nano Framework. The
Genie Nano requires Sapera version 8.00 or later.
Issues with uninstalling Cognex VisionPro with Sapera LT CamExpert
When the Cognex VisionPro package is uninstalled, the Genie Nano becomes not available within
CamExpert due to the Cognex uninstaller removing GigE Vision components. This forces a Genie
Nano user to reinstall the Network Imaging package (or execute a repair within Sapera LT).
Cognex VisionPro remains a useable third party product except for their uninstaller fault. Genie
Nano users just need to account for this issue until resolved by Cognex.
Summary of Contents for Genie Monochrome Series M1280
Page 179: ...Nano Series GigE Vision Camera Operational Reference 177...
Page 215: ...Nano Series GigE Vision Camera Technical Specifications 213 Note Genie Nano with C or CS Mount...
Page 237: ...Nano Series GigE Vision Camera Technical Specifications 235 Models M C5100 M C4090...
Page 252: ...250 Additional Reference Information Nano Series GigE Vision Camera...
Page 254: ...252 Additional Reference Information Nano Series GigE Vision Camera...