49391
Revision 3
10
Gasurveyor 700
USER MANUAL
Note: CSA have only assessed the LEL combustible gas detection portion of this
monitor for performance.
Note: CSA a seulement évalué la partie LIE pour la mesure des performances en
détection de gaz inflammables.
Note: The monitor performs internal checking of sensor sensitivity, which during
calibration will prevent the sensor being calibrated if it has been contaminated or
reached its end of life.
1.2.2 Certification and Approvals
The monitor has the following approvals:
Mark
ATEX
II 2 G Ex db ia IIC T4 Gb -20
o
C ≤ Ta ≤ 50
o
C
* II 2 G Ex db ia IIB T3 Gb -20
o
C ≤ Ta ≤ 50
o
C
SIRA 15 ATEX2299X
IECEx
Ex db ia IIC T4 Gb -20
o
C ≤ Ta ≤ 50
o
C
* Ex db ia IIB T3 Gb -20
o
C ≤ Ta ≤ 50
o
C
IECEx SIR 15.0105X
CSA
Class I, Div.1 Groups A, B, C and D T4
Class I, Zone 1 AEx db ia IIC T4 Gb Ex db ia IIC T4 Gb
* Class I, Div.1 Groups C and D T3
* Class I, Zone 1 AEx db ia IIB T3 Gb Ex db ia IIB T3 Gb
China
Ex d ia IIC T4 Gb
Ex d ia IIB T3 Gb (when fitted with semiconductor PPM sensor).
GB 3836.1-2010
GB 3836.2-2010
GB 3836.4-2010
* The GS7xx series is certified for use with for Gas Group IIC, Temperature Classification T4 except
when the Semiconductor gas sensor is fitted. With a semiconductor sensor fitted either internally or
externally the GS7xx is certified for Gas Group IIB and Temperature Classification T3.
1.2.3 Batteries
The GS700 has 2 battery options:
• Alkaline.
• Lithium-Ion rechargeable pack
Note:
See Section 6: Operator Maintenance
for more details.