Programming Manual
–
T3AWG3K-C Series Arbitrary Waveform Generator
True-Arb Operating Mode
65
2.16
Clock Group Commands
Command
ROSCillator
Description
This command and query sets or returns the frequency of the
Reference Clock parameter.
Group
Clock
Syntax
ROSCillator {MINimum|MAXimum|DEFault|<Herts>}
ROSCillator? [{MINimum|MAXimum}]
Related Commands
None
Arguments
<Hertz> ::= <NRf>
A single <NRf> value.
Returns
A single <NR3> value.
Example
ROSCillator 10E6
Set a frequency of the Reference Clock to10 MHz.
Table 71: ROSCillator
Command
AWGControl:SRATe
Description
This command sets or returns the sample rate for the Sampling Clock.
Group
Clock
Syntax
AWGControl:SRATe {MINimum|MAXimum|DEFault|<Hertz>}
AWGControl:SRATe? [{MINimum|MAXimum}]
Related Commands
ROSCillator
ROSCillator:SOURce
Arguments
<Hertz> ::= <NRf>
A single <NRf> value.
*RST sets this to the maximum value.
Returns
A single <NR3> value.
Example
AWGControl:SRATe 5E8
sets the clock sample rate to 500 MHz.
CLOCK:SRATE? might return 1.200009, indicating the clock
sample rate is set to 1.2 GHz.
Table 72: AWGControl:SRATe
Command
ROSCillator:SOURce
Description
This command sets the reference clock to either internal or external.