Programming Manual
–
T3AWG3K-C Series Arbitrary Waveform Generator
True-Arb Operating Mode
55
Table 54: DIGitals:LEVel[m]
Command
DIGital:NUMber
Description
This command and query sets or returns the available number of the
digital channels.
The maximum number of available digital lines depends on the AWG
model and on the installed license.
There are up to 8 digital lines every 2 analog channels.
Group
Output
Syntax
DIGitals:NUMber{0|2|4|6|8|10|12|14|16|18|20|22|24|26|28|30|32}
DIGitals:NUMber?
Note: enabling the digital lines will cause a decrease of resolution in the
analog output channels as shown in the user manual table (Digital
Channels section).
Related
Commands
None
Arguments
<value>::=<NR1>
The <value> indicates the available number of the digital channels.
Returns
<value>
Example
DIGital:NUMber 2
DIGital: NUMber?
Might returns “2”
Table 55: DIGital:NUMber
DIGitals:LEVel2?
Might return 2.5
Command
DIGitals:SKEW[m]
Description
This command and query sets or returns the Skew of the digital
output probe.
It sets the delay between the analog channels and the digital
channels in order to de-skew the analog and digital outputs. The
skew between analog/digital channels depends on the sampling
frequency: the minimum skew is 1 clock cycle @ the sampling
frequency.
Group
Output