4 – Electrical Installation
DPN 402196 Issue 4.1
© Teledyne TSS
4- 1
4 Electrical Installation
This section of the Manual explains how to connect the SDC and the sub-sea components of the
standard 440 System. You should attempt the electrical installation only after you have followed the
instructions in
Chapter 3 "Physical Installation"
to install the sub-assemblies of the 440 System.
Also included in this section are detailed instructions that tell you how to change the communication
method used between the SDC and the SEP.
NOTE
The standard 440 System uses RS232 communications. To select an alternative
communication method you must change the settings of links inside the SEP and
the switch on the rear of the SDC comms module. If the SDC being used is not an
SDC9 or SDC10, the current loop converter card will not have an external switch.
It will need to be modified by changing the internal links on the Current Loop Con-
verter board. If you need to change the communication method you
must
make
the necessary link adjustments inside the SEP
before
you mount it onto the ROV.
NOTE
The SDC provided with the 440 System is provided with Windows 7. DeepView for
Windows can be installed on an additional machine, but Teledyne TSS stress that
the operating system must have a minimum specification of Windows XP. The
specification of the SDC provided can be found in Section 8 "System Specifica-
tions” beginning on page 8-1. This should be used as a guideline if you are plan-
ning to use DeepView for Windows on an alternative PC.
4.1 Sub-sea Components
WARNING
There is a risk of death or serious injury by electric shock when you work on the
electrical distribution system. Only a competent engineer who has the relevant
training and experience should make the connection to the ROV electrical
distribution system.
Power-off the ROV and isolate the mains supply voltages before you connect the
440 System to the electrical distribution system. Observe all relevant local and
national safety regulations while you work on the ROV and on the 440 System.
Do not reconnect the mains electrical supply to the ROV or to the 440 System until
you have completed all work and you have fitted all safety covers and ground
connections.
This sub-section explains how to complete the electrical installation of the sub-sea components.
Summary of Contents for 440
Page 12: ...List of Figures x Teledyne TSS DPN 402196 Issue 4 1 ...
Page 18: ...Glossary xvi Teledyne TSS DPN 402196 Issue 4 1 ...
Page 24: ...1 Introduction 1 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 32: ...2 System Overview 2 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 66: ...4 Electrical Installation 4 20 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 88: ...5 Operating Software 5 22 Teledyne TSS DPN 402196 Issue 4 1 Figure 5 10 Altimeter Test ...
Page 144: ...6 Operating Procedure 6 40 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 154: ...7 Operational Considerations 7 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 164: ...8 System Specifications 8 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 203: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 17 Figure 10 15 SDC10 Dimensions ...
Page 230: ...A Operating Theory A 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 242: ...B Options B 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 244: ...C Altimeter C 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 246: ...D Reference D 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 248: ...D Reference D 4 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 250: ...D Reference D 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 252: ...D Reference D 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 254: ...D Reference D 10 Teledyne TSS DPN 402196 Issue 4 1 ...