4250 Flow Meter
Section 1 Introduction
1-11
Table 1-4 Technical Specifications for the Low Profile AV Sensor
Weight
2.1 lbs (.95 kg) including cable and connector
Sensor Dimensions
Length: 6.00 inches (15.2 cm)
Width: 1.31 inches (3.3 cm)
Height: 0.75 inches (1.9 cm)
Nose Angle
110° from horizontal
Wetted Sensor Material
Epoxy, chlorinated polyvinyl chloride (CPVC), Stainless-steel
Cable Material
Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC)
Cable Length
25 ft (7.6 m)
Maximum Distance (between sensor
and module)
75 ft (22.8 m) with optional extension cables. The distance can be extended
up to 1000 ft (300 m) with the optional Quick Disconnect Box.
Operating Temperature
32° to 122°F (0° to 50°C)
Storage Temperature
-40° to 160°F (-40° to 71°)
Level Measurement Range
0.033 to 10.0 ft (0.01 to 3.05 m)
Maximum Allowable level
20 ft (6.1 m)
Level Measurement Accuracy
0.033 to 5.0 ft: ± 0.008 ft/ft (0.01 to 1.52 m: ± 0.008 m/m)
>5.0 ft: ± 0.012 ft/ft (>1.52 m: ±0.012 m/m)
Accuracy per foot of change from calibrated depth @77°F (25°C). Includes
non-linearity and hysteresis.
Temperature Coefficient
±0.0023 ft/°F (±0.0013 m/°C)
Maximum error within operating temperature range at zero pressure (per
degree of change from calibration temperature).
Maximum Long-term Drift
0.033 ft
(±0.010 m)
Velocity Measurement Method
Doppler Ultrasonic
Frequency
500 kHz
Transmission Angle
20° from horizontal
Typical minimum depth for velocity
measurement
1 inch
(25 mm)
Range
-5 to +20 ft/s
(-1.5 to +6.1 m/s)
Velocity Accuracy
-5 to +5 ft/s (-1.5 to +1.5 m/s): ± 0.1 ft/s (±0.03 m/s)
5 to 20 ft/s (1.5 to 6.1 m/s): 2% of reading
Velocity accuracy for a uniform velocity profile in water with a
speed-of-sound of 4,850 ft/s.
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......