4250 Flow Meter
Section 1 Introduction
1-10
Table 1-3 Technical Specifications for the Standard AV Sensor
Weight Standard Range
Extended Range
2.1 lbs (.96 kg)
3.9 lbs (1.8 kg)
Sensor Dimensions
Length: 6.6 inches (6.8 cm)
Width: 1.6 inches (4.1 cm)
Height: 1.2 inches (3.0 cm)
Nose Angle
35° from horizontal
Cable Length Standard Range
Extended Range
25 ft (7.6 m)
50 ft (15.2 m)
Materials
Sensor: Polybutadiene-based polyurethane, stainless-steel
Cable: Polyvinyl chloride (PVC) chlorinated polyvinyl chloride (CPVC)
Operating Temperature
32° to 160°F (0° to 71°C)
Level Measurement Method
Submerged pressure transducer mounted in the flow stream
Transducer Type
Differential linear integrated circuit pressure transducer
Level Measurement Range
Standard Range
Extended Range
0.05 to 10.0 ft (0.015 to 3.05 m)
0.05 to 30.0 ft (0.015 to 9.14 m)
Maximum Allowable level
Standard Range
Extended Range
20 ft (6.1 m)
40 ft (12.2 m)
Level Measurement Accuracy
Standard Range
Extended Range
0.033 to 5.0 ft: ± 0.008 ft/ft (0.01 to 1.52 m: ± 0.008 m/m)
>5.0 ft: ± 0.012 ft/ft (>1.52 m: ± 0.012 m/m)
0.05 to 15.0 ft: ± 0.03 ft (0.015 to 4.57 m: ± 0.009 m)
0.05 to 21.0 ft: ± 0.09 ft (0.015 to 6.40 m: ± 0.027 m)
0.05 to 30.0 ft: ± 0.30 ft (0.015 to 9.14 m: ± 0.090 m)
@77°F (25°C). Includes non-linearity, repeatability, and hysteresis. Does
not include temperature coefficient.
Compensated Temperature Range
32° to 100°F (0° to 38°C)
Temperature Coefficient
Standard Range
Extended Range
0.05 to 4.0 ft: ± 0.005 ft/°F (0.015 to 1.22 m: ± 0.0027 m/°C)
4.0 to 10.0 ft: ± 0.007 ft/°F (1.22 to 3.05 m: ± 0.0038 m/°C)
0.05 to 30.0 ft: ± 0.008 ft/°F (0.015 to 9.14 m: ± 0.0044 m/°C)
Maximum error over compensated temperature range, per degree of tem-
perature change.
Velocity Measurement Method
Doppler Ultrasonic
Frequency
500 kHz
Typical minimum depth for velocity
measurement
0.25 ft (75 mm)
Range
-5 to +20 ft/s (-1.5 to +6.1 m/s)
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......