3700 Portable Samplers
Section 1 Introduction
1-8
• 9400 liter (2.5 gallon) polyethylene composite bottle
with unlined cap
1.4 Power Options
The sampler is powered by a 12 VDC power source, either a
rechargeable nickel-cadmium battery, a lead-acid rechargeable
battery, or an AC-powered 12-VDC regulated supply.
CAUTION
If you use a 120 or 240 volt AC-connected Power Pack, the AC
line cord is the "Disconnect Device." Always install the sampler
with the line cord and plug visible and readily accessible, so
that power can be disconnected easily.
For complete information on power options and their mainte-
nance, consult the Teledyne Isco
Power Products Guide
, which
was also shipped with your sampler. You can order additional
copies of the
Power Products Guide
by contacting Teledyne Isco’s
Customer Service Department at 800-228-4373 in the U.S.A.
1.5 Compatible
Equipment
CAUTION
Most Teledyne Isco accessories and interfacing equipment are
not certified for use in "Hazardous Locations," as defined by
the National Electrical Code. Never operate equipment in haz-
ardous locations that has not been certified as safe for such
use.
The Teledyne Isco 2151 and 2151P Area Velocity Flow Mod-
ules are certified intrinsically safe for installation in Class I,
Division 1, Groups C and D hazardous locations.
A full line of accessories and interfacing equipment is available
to help you adapt the sampler to your specific application; some
of the more common items are briefly discussed below. Other
accessories are noted throughout this manual, where appro-
priate.You will find a full list of accessories in Appendix B.
1.5.1 Isco Flow Meters
The 4200 Series Flow Meters, 2100 Series Flow Modules, and
4100 Series Flow Loggers, and UniMag Closed-Pipe Flow Meters,
are collectively called “flow meters” in this manual. The 3700
Series will accept flow pulses from all Isco Flow meters for
flow-paced sampling. Isco Flow meters and flow loggers are
equipped with a sampler-enable feature. The 4200 Series Flow
Meters and 4100 Series Flow Loggers can inhibit a 3700 until the
level of the flow stream reaches a predetermined height or “set
point.”
When the flow stream reaches that height, the flow meter
enables the sampler and starts the sampling routine. If the level
of the stream falls below the set point, the flow meter can disable
the sampler and halt the routine.
Summary of Contents for 3700
Page 2: ......
Page 4: ......
Page 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Page 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Page 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Page 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Page 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Page 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Page 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Page 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Page 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Page 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Page 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Page 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Page 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Page 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Page 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Page 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Page 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Page 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Page 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Page 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Page 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Page 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Page 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Page 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Page 238: ......
Page 240: ......
Page 242: ......