The first step is to turn on the
MODEM ENABLE
communication mode (Mode 64,
Section 6.10.2.11). Once this is completed, the appropriate setup command line for your
modem can be entered into the analyzer. The default setting for this feature is
AT Y0 &D0 &H0 &I0 S0=2 &B0 &N6 &M0 E0 Q1 &W0
This string can be altered to match your modem’s initialization and can be up to 100
characters long.
To change this setting press:
SETUP X.X
COMMUNICATIONS MENU
ID
COM1
COM2
EXIT
Select which
COM Port is
tested
SETUP X.X
PRIMARY SETUP MENU
CFG DAS
RNGE
PASS CLK
MORE
EXIT
SETUP X.X
SECONDARY SETUP MENU
COMM
VARS DIAG
EXIT
SAMPLE RANGE = 500.0 PPB NOX=X.X
< TST TST > CAL
SETUP
EXIT
returns
to the
previous
menu
SETUP X.X
COM1 MODEM INIT:AT Y
∅
&D
∅
&H
<SET SET>
EDIT
EXIT
S
ETUP X.X COM1 MODEM INIT:
[A]
T Y
∅
&D
∅
&H
<CH CH> INS DEL [A]
ENTR
EXIT
SETUP X.X
COM1 MODE:0
SET>
EDIT
EXIT
SETUP X.X COM1 BAUD RATE:19200
<SET
SET>
EDIT
EXIT
ENTR
accepts the
new string and returns
to the previous menu.
EXIT
ignores the new
string and returns to
the previous menu.
The
<CH
and
CH>
keys move the
[ ]
cursor left and right
along the text
string
The
INS
key
inserts a character
before the cursor
location.
Press the
[?]
key
repeatedly to cycle through the
available character set:
0-9
A-Z
space ’ ~ !
# $ % ^ & * ( ) - _ =
+[ ] { } < >\ | ; : , . / ?
The
DEL
key
deletes a character
at the cursor
location.
6.11.4. COM Port Password Security
In order to provide security for remote access of the M200E, a LOGON feature can be
enabled to require a password before the instrument will accept commands. This is done by
turning on the
SECURITY MODE
(Mode 4, Section 6.10.2.11). Once the
SECURITY MODE
is enabled, the following items apply.
•
A password is required before the port will respond or pass on commands.
•
If the port is inactive for one hour, it will automatically logoff, which can also be
achieved with the LOGOFF command.
•
Three unsuccessful attempts to log on with an incorrect password will cause subse-
quent logins to be disabled for 1 hour, even if the correct password is used.
•
If not logged on, the only active command is the '?' request for the help screen.
•
The following messages will be returned at logon:
•
LOGON SUCCESSFUL - Correct password given.
•
LOGON FAILED - Password not given or incorrect.
•
LOGOFF SUCCESSFUL - Connection terminated successfully.
To log on to the model 200E analyzer with
SECURITY MODE
feature enabled, type:
106
044100102 Rev A
Summary of Contents for 200E
Page 15: ...M200E Documentation Model 200E Instruction Manual USER NOTES xiv 044100102 Rev A ...
Page 19: ...M200E Documentation Model 200E Instruction Manual USER NOTES 4 044100102 Rev A ...
Page 141: ...Calibration Procedures Model 200E Instruction Manual USER NOTES 126 044100102 Rev A ...
Page 203: ...Theory of Operation Model 200E Instruction Manual USER NOTES 188 044100102 Rev A ...
Page 239: ...Troubleshooting Repair Model 200E Instruction Manual USER NOTES 224 044100102 Rev A ...
Page 265: ...APPENDIX A Model 200E Instruction Manual USER NOTES 250 044100110 Rev A ...
Page 271: ...APPENDIX B Model 200E Instruction Manual USER NOTES 256 044100120 Rev A ...
Page 275: ...APPENDIX D Model 200E Instruction Manual 260 044100141 Rev A USER NOTES ...