Table 9-5: Model 200A Internal Variables
No.
Name
Units
Default
Value
Value
Range
Description
0
DAS_HOLD_OFF
min
15
0-60
Time that data is not put into
DAS after CAL or DIAG
modes
1 TPC_ENABLE
Logic OFF ON-OFF
Temp/Pres
compensation
enable
2
DYN_ZERO
Logic
OFF
ON-OFF
Enable zero calibration during
rear panel contact closure zero
mode
3
DYN_SPAN
Logic
OFF
ON-OFF
Enable span calibration during
rear panel contact closure
span mode
4
SFLOW_SET
cc/min.
500
400-1000
Nominal sample flow rate
5
OFLOW_SET
cc/min.
80
0-500
Nominal ozone flow rate
6 IZS_SET
°
C
50
30-70
IZS temperature set point
7 RS232_MODE
Bit
Field
0
0-99999
Value is SUM of following
decimal numbers:
1=enable quiet mode
2=enable computer mode
4=enable security feature
8=enable front panel RS-232
menus
16=enable alternate protocol
32=enable multidrop protocol
8
CLOCK_ADJ
Sec.
0
+-60
Real-time clock speed
adjustment
9
CAL_ON_NO2
OFF
ON-OFF
Enable calibrate on NO
2
perm
tube
9.1.5 Test Channel Analog Output
Many of the TEST functions have an analog voltage associated with them. As a diagnostic aid it
is possible to route the various test voltages out the 4th analog output.
9-20
Summary of Contents for 200A
Page 10: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK x ...
Page 12: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 1 2 ...
Page 26: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 2 14 ...
Page 40: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 4 10 ...
Page 126: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 7 38 ...
Page 210: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 9 68 ...
Page 218: ...Teledyne API Model 200A NOX Analyzer Instruction Manual 02246 Rev F1 INTENTIONALLY BLANK 10 8 ...