Vertical Beam Profile Commands
The following commands define the criteria used to collect the vertical beam profile data.
Vertical beam profiling extends the ping time approximately 25%. Ping time depends on
water depth and number of bins.
Available Vertical Beam Profile Commands
This section lists the vertical beam profile commands.
>Z?
Available Commands:
ZP -01 ------------------ Number of Pings [0-999, -1=WP]
Z? ---------------------- Display Z-Command Menu
>#Z?
*** CAUTION: These commands are reserved for RDI use
and may not be currently supported!
Available Commands:
#ZB -1 ------------------ Bandwidth [0=Wide, 1=Narrow, -1=WB]
#ZC -01 ----------------- Correlation Threshold (counts) [0..255,-1=WC]
#ZD 0000000001 ---------- Data Out [{v;c;a;p;s;*;*;*;*;wd},-1=WD]
#ZF -01 ----------------- Blanking Distance (cm) [0-9999,-1=WF]
#ZJ -1 ------------------ Gain [0=low, 1=high,-1=WJ]
#ZM -1 ------------------ V-Beam Profile Mode [2,-1=WM]
#ZN -01 ----------------- Number of Bins [1-200,-1=WN]
#ZP -01 ----------------- Number of Pings [0-999, -1=WP]
#ZS -01 ----------------- Bin Size (cm) [60-480, -1=WS]
#ZV -01 ----------------- Ambiguity Velocity (cm/s) [2-700,-1=WC/cos(angle)]
#Z? --------------------- Display Z-Command Menu
>
Standard Vertical Beam Profile Commands
ZP – Vertical Beam Number of Pings
Purpose:
Sets the number of vertical beam pings to average in each data ensemble.
Format:
#ZPnnn
Range:
nnn = 0 to 999 pings, -1 = same as WP command
Default:
#ZP-1
Recommended Setting.
The default setting for this command is recommended for most applications.
Description: ZP sets the number of vertical beam pings to average in each ensemble before sending/re-
cording the data. The setting ZP0 disables vertical beam profiling.